Final | 1/24/2020 | 1/24/2020 | 1/24/2020 | P | PASS |
Brian Scoles
|
|
|
Ac 4343 Phone #: ###-#### Inspection requested via web by Gary Reeves- final ok
|
Final | 1/23/2020 | 1/24/2020 | 1/24/2020 | A | FAIL |
Jack Reynolds
|
|
|
ac 4343 Phone #: ###-#### Inspection requested via web by Gary Reeves - A/C needs locking caps installed on service ports - A/C needs leveled. Landscaping and site work on side of house is not complete
|
Rough-in | 10/29/2019 | 10/30/2019 | 10/30/2019 | A | PASS |
Brian Scoles
|
|
|
Phone #: ###-#### Inspection requested via web by Gary Reeves- R/I ok- need to seal R/A can where outside air was removed and patched by final- could not see if sealed on inside since filter was installed in can
|
Pressure Test | 10/29/2019 | 10/30/2019 | 10/30/2019 | A | PASS |
Brian Scoles
|
|
|
Phone #: ###-#### Inspection requested via web by Gary Reeves- 20lb gas pass- tagged meter location
|
Rough-in | 10/21/2019 | 10/22/2019 | 10/22/2019 | P | FAIL |
Brian Scoles
|
|
|
Phone #: ###-#### Inspection requested via web by Gary Reeves 1- need city approved man j onsite 2- gas gauge doesnt zero out 3- 6" fresh air can not come from R/A can needs tied into R/A plenum at furnace
left notice front window
|
Pressure Test | 10/21/2019 | 10/22/2019 | 10/22/2019 | P | FAIL |
Brian Scoles
|
|
|
Phone #: ###-#### Inspection requested via web by Gary Reeves- gauge doesnt zero out
|