Final | 1/14/2020 | 1/14/2020 | 1/14/2020 | P | PASS |
Brian Scoles
|
|
|
Phone #: ###-#### Inspection requested via web by Bob Ferrin- final ok
|
Final | 1/9/2020 | 1/10/2020 | 1/10/2020 | A | FAIL |
Brian Scoles
|
|
|
Phone #: ###-#### Inspection requested via web by Bob Ferrin 1- need to seal exterior gas line penetration at meter location weather tight 2- need upper combustion air grill installed in furnace door 3- need locking caps on a/c service ports 4- need air balance report onsite none found
|
Rough-in | 9/26/2019 | 9/27/2019 | 9/27/2019 | A | PASS |
Brian Scoles
|
|
|
Phone #: ###-#### Inspection requested via web by Bob Ferrin- R/I ok- check combustion air for water heater closet at final
|
Pressure Test | 9/27/2019 | 9/27/2019 | 9/27/2019 | A | PASS |
Brian Scoles
|
|
|
Phone #: ###-#### Inspection requested via web by Bob Ferrin- 20lb gas pass- tagged meter location
|