Complete HVAC Installation: Install furnace, ductwork, venting for exhaust fans and range hood, gas piping for water heater
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final5/29/20205/29/20205/29/2020APASS
DetailsBrian Scoles
Please call installer on way at ###-#### and call Ryan with questions at ###-####. Thank you Phone #: ###-#### Inspection requested via web by Rhonda Marcum- final ok
Conference5/29/20205/29/20205/29/2020APASS
DetailsBrian Scoles
To Witness duct blast, please call installer on way at ###-#### and call Ryan with questions at ###-####. Thank you Phone #: ###-#### Inspection requested via web by Rhonda Marcum- duct blast test pass
Final5/28/20205/28/20205/28/2020ANR
DetailsBrian Scoles
Waiting for approved manual J from city, please homeowner 30 minutes in advance for access at ###-#### call Ryan with any questions at ###-####. Thank you Phone #: ###-#### Inspection requested via web by Rhonda Marcum
1- need approved man j onsite
2- need to remove enclosure around range duct to verify seal and ducting
3- need to witness duct blast test
4- need to filter outside air in attic since has filter grills installed
5- need locking caps on condenser

schedule duct blast test when ready
Mec-Aging Inspection4/27/20204/27/20204/27/2020 CANC
DetailsBrian Scoles
needs called in for final when ready- WIP
Rough-in10/17/201910/17/201910/17/2019APASS
DetailsBrian Scoles
Please call Ryan with any questions at ###-####. Thank you Phone #: ###-#### Inspection requested via web by Rhonda Marcum- R/I ok- equipment not set check at final- left sticker in YMC folder on plan table
Rough-in10/15/201910/15/201910/15/2019PFAIL
DetailsBrian Scoles
Please call James with any questions at ###-####. Thank you Phone #: ###-#### Inspection requested via web by Rhonda Marcum-
1- need to fix all rips and tears in arma flex in wall and attic
2- need to install 18" R/A in hallway per approved man j in hallway

left notice front of YMC folder
Rough-in10/4/201910/7/201910/7/2019AFAIL
DetailsBrian Scoles
Please call Ryan with any questions or concerns at ###-####. Thank you Phone #: ###-#### Inspection requested via web by Rhonda Marcum
1- need to resubmit man j for the way ducting is ran now or run per approved man j- supply and R/A duct missing or ran different
2- is W/H flue solid core pvc for tanlless water heater can not see labeling on PVC? needs vent thru roof to maintain 10' from property line and maintain 10' or 3' from outside air intake

left notice YMC folder
Pressure Test10/7/201910/7/201910/7/2019APASS
DetailsBrian Scoles
Please call Ryan with any questions or concerns at ###-####. Thank you Phone #: ###-#### Inspection requested via web by Rhonda Marcum- 20 lb gas pass- tagged meter location
Rough-in10/4/201910/4/201910/4/2019AFAIL
DetailsBrian Scoles
Please call Ryan with any question or concerns at ###-####. Thank you Phone #: ###-#### Inspection requested via web by Rhonda Marcum- no corrections have been made
Rough-in10/3/201910/3/201910/3/2019AFAIL
DetailsBrian Scoles
Please call Ryan with any questions at ###-####. Thank you Phone #: ###-#### Inspection requested via web by Rhonda Marcum-
1- need city approved man j onsite
2- gas test failed
3- need top seal supplu and R/A boots on all spot weld seams
4- need to seal and insulate supply reducer and insulate in attic above living room
5- need to insulate bare metal in attic on supply trunk above master bath
6- water heater flue or is it electric?

left correction notice in YMC folder on print table
Pressure Test10/3/201910/3/201910/3/2019AFAIL
DetailsBrian Scoles
Please call Ryan with any questions at ###-####. Thank you Phone #: ###-#### Inspection requested via web by Rhonda Marcum- gas test failed gauge at 12 psi