Permit Information
Permit NumberMEC19-04610
StatusFinaled
Name TVR INC
Site Address 8506 W OVERLAND RD
Project Name 
Customer Number 
ePlanReviewNo
Description
New: Exhaust systems, tube heaters and flue venting
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final12/30/201912/31/201912/31/2019APASS
DetailsBrian Scoles
Final Phone #: ###-#### Inspection requested via web by Brandon Sorensen- final ok- no card onsite to sign- GC not onsite
Card not on site to sign12/31/201912/31/201912/31/2019APASS
DetailsBrian Scoles
Final Phone #: ###-#### Inspection requested via web by Brandon Sorensen- card not onsite- GC not onsite
Final12/24/201912/26/201912/26/2019AFAIL
DetailsBrian Scoles
Final Phone #: ###-#### Inspection requested via web by Brandon Sorensen- b vent on tube heater needs 1" clearance to combustilbles thru roof, roofing membrane needs removed and pipe extend up 12" above roof and install storm collar- boiler exhaust flue need secured to hangers and one installed on wall for intake- went over onsite with general contractor- temp occupancy ok
Rough-in12/23/201912/23/201912/23/2019PPASS
DetailsBrian Scoles
insulation and flex and registers ok- ok for ceiling tiles- tube heater penetration on roof needs 1" clearance to b vent on roof by final- right now is roofed onto b vent-
Rough-in11/26/201911/27/201911/27/2019APART
DetailsBrian Scoles
cover inspection Phone #: ###-#### Inspection requested via web by Brandon Sorensen- registers flex and insulation ok on ducting installed- still need to see square to rounds insulated completely- will send pic then ok for cover of ceiling
Rough-in11/6/201911/7/201911/7/2019APASS
DetailsBrian Scoles
cover Phone #: ###-#### Inspection requested via web by Brandon Sorensen- insulation on duct installed ok- need to finish insulation on square to round fittings will look at that on grid inspection- will need ladder to access above hard lid in bathroom sheetrock installed already with out approval- called contractor listed and talked to him about this
Rough-in10/14/201910/15/201910/15/2019APART
DetailsBrian Scoles
sealer inspection Phone #: ###-#### Inspection requested via web by Brandon Sorensen- approved prints onsite- seal on duct in office area ok- ok to insulate- call in another R/I inspection when unit heaters and exhaust duct completed