Information based on query as of Wednesday, July 3, 2024.
Permit Information
Permit NumberMEC19-04643
StatusFinaled
Name ALLEY HEATING & COOLING
Site Address 10604 W CRUSER DR
Project Name 
Customer Number 
ePlanReviewNo
Description
Complete HVAC Installation: furn,ac,bath vent,dr vent,kitch vent,gas pipe
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final12/10/201912/11/201912/11/2019APASS
DetailsBrian Scoles
Phone #: ###-#### Inspection requested via web by Oleg Chervak- final ok
Rough-in10/22/201910/22/201910/22/2019PPASS
DetailsBrian Scoles
we have approved manual on site now, please re-inspect Phone #: ###-#### Inspection requested via web by Oleg Chervak- R/I ok
Rough-in10/17/201910/18/201910/18/2019PFAIL
DetailsBrian Scoles
Phone #: ###-#### Inspection requested via web by Oleg Chervak- need approved man j with right address onsite with right equipment- man j onsite for 10600 address- man j approved at this address has amana equipment
Rough-in10/17/201910/17/201910/17/2019PFAIL
DetailsBrian Scoles
corrections made, please re-inspect, please come AM Phone #: ###-#### Inspection requested via web by Oleg Chervak
1- need approved man j onsite with right equipment brand and approved from city
2- insulation shield has gap off metal in attic insulation can come in contact with b vent for w/h
Rough-in10/15/201910/16/201910/16/2019AFAIL
DetailsBrian Scoles
Phone #: ###-#### Inspection requested via web by Oleg Chervak
1- need ladder provided by contractor to access furnace/coil in attic
2- missing transfer in bedroom 2
3- need to seal dryer duct to termination box
4- need to fix/replace arma flex in wall attic bare copper showing
5- 6" outside air can not come from R/A can needs tied into R/A plenum at furnace- remove tap seal and insulate to r-6 over patch

left notice front window
Pressure Test10/15/201910/16/201910/16/2019APASS
DetailsBrian Scoles
Phone #: ###-#### Inspection requested via web by Oleg Chervak- 20lb gas pass tagged meter location