Final | 12/19/2019 | 12/20/2019 | 12/20/2019 | P | PASS |
Brian Scoles
|
|
|
Client is available from 12-4pm, you can call ahead but they will be there. Mr. and Mrs Carlson. Phone #: ###-#### Inspection requested via web by Andrea Grigsby
|
Final | 10/18/2019 | 10/21/2019 | 10/21/2019 | P | FAIL |
Brian Scoles
|
|
|
Mr. Carlson will be home from 12-4pm. He doesn''t answer the phone so just come for inspection. Phone #: ###-#### Inspection requested via web by Andrea Grigsby- mini split ok- pvc drain primary need 6" clearance to single wall pipe- need metal doors installed on closet with minimum 3" clearance to front of furnace- need 3 screws in flue- W/H pan needs 1" clearance all the way around- need electrical permit issed for condenser on mini split
|