Final | 2/13/2020 | 2/14/2020 | 2/14/2020 | A | PASS |
Brian Scoles
|
|
|
Bruce Phone #: ###-####- final ok
|
Final | 2/12/2020 | 2/13/2020 | 2/13/2020 | A | FAIL |
Brian Scoles
|
|
|
Special instructions for access...please call 5 - 10 minutes before you arrive. thank you.... Phone #: ###-#### Inspection requested via web by Bruce Lacy 1- need to seal exterior lineset penetration 2- need 90 degree pvc on condesate drain outside and seal weather tight thru foundation 3- need to seal gas piping thru wall at meter 4- need 6" clearance from flue to pvc drain in closet 5- need to add pipe to dryer duct in laundry room 6- seal condensate at floor in furnace closet where penetrates into crawl
|
Rough-in | 11/11/2019 | 11/12/2019 | 11/12/2019 | P | PASS |
Troy James
|
|
|
Duct blast test has been completed-- approved plans in packet by water heaters tubing in mechanical closet area. Inspection requested via web by Bruce Lacy 20# gas test, No equipment onsite. Need to verify correct equipment at final.
|
Rough-in | 11/9/2019 | 11/12/2019 | 11/11/2019 | A | CANC |
Brian Scoles
|
|
|
Duct blast has been performed...approved plans at water heater /mech. closet area Phone #: ###-#### >> Inspection requested via web by Bruce Lacy Inspection cancelled from web by: Bruce Lacy
|