Final | 1/27/2020 | 1/27/2020 | 1/27/2020 | P | PASS |
Brian Scoles
|
|
|
Bj 5730755m code is 7777 Inspection requested via web by william kerwin- final ok
|
Final | 1/20/2020 | 1/21/2020 | 1/21/2020 | P | FAIL |
Brian Scoles
|
|
|
Lock box code is 7777. Bj ###-#### Inspection requested via web by william kerwin 1- need duct blast and air balance report onsite 2- need approved man j onsite 3- seal exterior gas line penetrations
|
Rough-in | 10/23/2019 | 10/23/2019 | 10/23/2019 | P | PASS |
Brian Scoles
|
|
|
Code 7777 Phone #: ###-#### Inspection requested via web by Teresa Costello- R/I ok
|
Rough-in | 10/21/2019 | 10/22/2019 | 10/22/2019 | A | FAIL |
Brian Scoles
|
|
|
Codeb7777 Inspection requested via web by william kerwin 1- need approved man j from city onsite 2- need ladder provided by contractor to access furn/coil in attic 3- need transfer in bedroom 4- need to seal all exhaust fan connections where metal fitting ties onto plastic 5- b vent in attic does not have 1" clearance to truss and roof and nylon strap laying against it 6- range duct not installed
left correction notice front window
|
Pressure Test | 10/21/2019 | 10/22/2019 | 10/22/2019 | A | PASS |
Brian Scoles
|
|
|
Codeb7777 Inspection requested via web by william kerwin- 20lb gas pass tagged meter location
|