Information based on query as of Thursday, June 20, 2024.
Permit Information
Permit NumberMEC19-05450
StatusFinaled
Name TVR INC
Site Address 9300 W OVERLAND RD Unit: SUITE 200
Project Name 
Customer Number 
ePlanReviewNo
Description
Addition: Reuse existing supply trunks as per zone map
Reuse existing return trunks as per zone map
Demo existing supply and return duct that cannot be reused for current plans
Provide and Install new supply and return main and branch duct to match diff
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final2/10/20202/11/20202/11/2020APASS
DetailsBrian Scoles
FINAL Phone #: ###-#### Inspection requested via web by Brandon Sorensen- final ok- card signed
Rough-in1/30/20201/30/20201/30/2020PPASS
DetailsBrian Scoles
Corrections have been made- ok for ceiling tiles all areas- has air balance been completed??- call in final when ready
Rough-in1/28/20201/29/20201/29/2020APASS
DetailsBrian Scoles
Cover inspection - call Josh Phone #: ###-#### Inspection requested via web by Brandon Sorensen- center stairwell east side rooms insulation, flex and registers all good excluding skills lab need to cap abandoned exhaust in ceiling, staff work area needs supply duct lengthened and register installed per reflected ceiling print and learning resorce room needs supplies and R/ A ducting capped above ceiling- call in final when ready- has air balance been completed??
Rough-in1/23/20201/24/20201/24/2020APASS
DetailsBrian Scoles
partial cover Phone #: ###-#### Inspection requested via web by Brandon Sorensen- center stairwell west all rooms ok for ceiling grid except for 4 misc rooms- will look at next week on east half
Rough-in1/14/20201/15/20201/15/2020APART
DetailsBrian Scoles
sealer inspection Phone #: ###-#### Inspection requested via web by Brandon Sorensen- seal on duct ok per check marks on contractors print ok for insulation- still couple offices to see for seal installing now
Rough-in1/7/20201/8/20201/8/2020APART
DetailsBrian Scoles
partial seal and rough in Phone #: ###-#### Inspection requested via web by Brandon Sorensen- seal east side on rooms only checked off on prints- west side all good on seal- ok for insulation-
Rough-in12/27/201912/30/201912/30/2019APART
DetailsBrian Scoles
Duct Seal Inspection Phone #: ###-#### Inspection requested via web by Brandon Sorensen- center stairwell to west seal on all duct ok ok ti insulate excluding 3 rooms and existing RTU to move- call in when ready