Permit Information
Permit NumberMEC20-00501
StatusFinaled
Name TVR INC
Site Address 10255 W OVERLAND RD
Project Name 
Customer Number 
ePlanReviewNo
Description
Addition: Demo existing HVAC as per plans and phasing plan
Provide and Install 6 each Carrier Split Systems with accessories as per plans and specifications
Provide and Install venting for split systems and water heater as per plans and specifications
Pro
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final8/13/20208/13/20208/13/2020PPASS
DetailsBrian Scoles
final Phone #: ###-#### Inspection requested via web by Brandon Sorensen- final ok- card signed
Rough-in7/31/20208/3/20208/3/2020APASS
DetailsBrian Scoles
cover inspection Phone #: ###-#### Inspection requested via web by Brandon Sorensen- ceiling cover in lobby 106 ok for ceiling tiles
Rough-in7/28/20207/28/20207/28/2020PPASS
DetailsChad Schwendiman
cover Phone #: ###-#### Inspection requested via web by Brandon Sorensen - Okay to cover grid ceilings in the south west corner of the 1st floor
Rough-in7/27/20207/27/20207/27/2020PPASS
DetailsChad Schwendiman
duct seal inspection Phone #: ###-#### Inspection requested via web by Brandon Sorensen - Duct seal pass for duct work in crawl
Rough-in7/13/20207/13/20207/13/2020PPASS
DetailsBrian Scoles
cover for flues in walls Phone #: ###-#### Inspection requested via web by Brandon Sorensen- 3" PVC exhaust and intake in wall ok- ok to cover
Rough-in7/9/20207/10/20207/10/2020APART
DetailsBrian Scoles
sealer inspection for attic area Phone #: ###-#### Inspection requested via web by Brandon Sorensen- seal on return and exhaust in attic ok- ok to insulate- 4 exhaust fans ok to cover hard lids
Rough-in7/6/20207/7/20207/7/2020APASS
DetailsBrian Scoles
wall cover inspection - call cy Phone #: ###-#### Inspection requested via web by Brandon Sorensen- pvc flues in wall ok to cover- contractor will pressure test at final
Final5/26/20205/27/20205/27/2020APART
DetailsBrian Scoles
temp final for SARMC - call cyrus Phone #: ###-#### Inspection requested via web by Brandon Sorensen- phase 2 temp occupancy ok- ok for ceilings
Rough-in5/12/20205/13/20205/13/2020APASS
DetailsBrian Scoles
cover for hard lid inspection Phone #: ###-#### Inspection requested via web by Brandon Sorensen- phase 2 hard lid bathroom ok to cover
Rough-in4/30/20205/4/20205/4/2020APASS
DetailsBrian Scoles
cover - call cy Phone #: ###-#### Inspection requested via web by Brandon Sorensen- phase 2 duct insulation ok- ok for ceiling grid
Rough-in4/29/20204/30/20204/30/2020APART
DetailsBrian Scoles
duct seal inspection Phone #: ###-#### Inspection requested via web by Brandon Sorensen- phase 2 seal on supply and return ducts ok- marked approved prints with colored marker for this phase
Final4/15/20204/16/20204/16/2020APART
DetailsBrian Scoles
Temp occupancy - call cy Phone #: ###-#### Inspection requested via web by Brandon Sorensen- temp occupancy phase 1 only ok
Rough-in3/31/20204/1/20204/1/2020APASS
DetailsBrian Scoles
cover Phone #: ###-#### Inspection requested via web by Brandon Sorensen- Phase 1 registers flex and insulation in crawl and attic ok- Phase 1 only ok for ceiling tiles- initialed approved prints
Rough-in3/9/20203/10/20203/10/2020APART
DetailsBrian Scoles
sealer inspection Phone #: ###-#### Inspection requested via web by Brandon Sorensen- Phase 1 seal on duct ok- ok to insulate in attic and crawl- colored approved prints for ducts completed at this time and initaled crawl and attic prints- exhaust fan in bathroom ok for hard lid cover- recall in when insulation completed