Final | 3/19/2020 | 3/20/2020 | 3/20/2020 | A | PASS |
Brian Scoles
|
|
|
Phone #: ###-#### Inspection requested via web by Brandon Sorensen- final ok- card signed
|
Final | 3/17/2020 | 3/17/2020 | 3/17/2020 | P | PART |
Brian Scoles
|
|
|
Phone #: ###-#### Inspection requested via web by Brandon Sorensen- need plenum rated material for drain off ceiling mini split no pvc allowed- need protection on lineset on roof bare copper showing- mini split mc cable does not meet amp rating- talked with GC, electrician and service tech onsite- should have been a R/I inspection on this before final was called in
|