Final | 6/16/2020 | 6/17/2020 | 6/17/2020 | A | PASS |
Brian Scoles
|
|
|
the correct ac installed, please re-inspect garage code 0425 or 3484 1225 Phone #: ###-#### Inspection requested via web by Oleg Chervak- final ok
|
Final | 6/12/2020 | 6/15/2020 | 6/15/2020 | P | FAIL |
Brian Scoles
|
|
|
garage code 0425 or 3484 or 1225 Phone #: ###-#### Inspection requested via web by Oleg Chervak- condenser installed does not match approved man j shows carrier has payne installed- replace with right equipment and reschedule
|
Rough-in | 4/22/2020 | 4/22/2020 | 4/22/2020 | P | PASS |
Brian Scoles
|
|
|
WE HAVE NEW APPROVED MANUAL J ON SITE, PLEASE REINSPECT CORRECTIONS MADE. Phone #: ###-#### Inspection requested via web by Oleg Chervak- R/I on HVAC and fireplace ok
|
Rough-in | 4/21/2020 | 4/21/2020 | 4/21/2020 | P | FAIL |
Brian Scoles
|
|
|
WE UPDATED THE MANUAL J TO REFLECT THE EQUIPMENT ALSO SENT IN FOR RE-REVIEW. CORRECTIONS MADE AS REQUESTED WE WILL HAVE NEW MANUAL J ON SITE FOR YOU. PLEASE CHECK FOR APPROVED ON FINAL. Phone #: ###-#### Inspection requested via web by Oleg Chervak 1- need resubmitted city approved man j onsite for inspection 2- primary condensate needs undo stress above washer box relieved and nuisance drain has a trap in it needs 1/4" per foot grade to outside
notice still posted
|
Pressure Test | 4/21/2020 | 4/21/2020 | 4/21/2020 | P | PASS |
Brian Scoles
|
|
|
WE UPDATED THE MANUAL J TO REFLECT THE EQUIPMENT ALSO SENT IN FOR RE-REVIEW. CORRECTIONS MADE AS REQUESTED WE WILL HAVE NEW MANUAL J ON SITE FOR YOU. PLEASE CHECK FOR APPROVED ON FINAL. Phone #: ###-#### Inspection requested via web by Oleg Chervak- 20lb gas pass
|
Rough-in | 4/20/2020 | 4/20/2020 | 4/20/2020 | P | FAIL |
Brian Scoles
|
|
|
Phone #: ###-#### Inspection requested via web by Oleg Chervak 1- gas gauge doesnt zero out- throw away 2- resubmit man j for approved equipment installed show payne with carrier installed 3- condensate drains both need 1/4" grade to outside per foot and use approved hangers drives not acceptable 4- b vent for w/h in garage will not have 1" clearance after sheetrock will be installed on ceiling and wall- need to firecaulk second floor at floor and attic in chase 5- return needs filter box installed
left notice back window
|
Pressure Test | 4/20/2020 | 4/20/2020 | 4/20/2020 | P | FAIL |
Brian Scoles
|
|
|
Phone #: ###-#### Inspection requested via web by Oleg Chervak- gauge doesnt xero out- throw gauge away
|