Permit Information
Permit NumberMEC20-01589
StatusIssued
Name TML LLC
Site Address 205 W HIGHLAND VIEW DR
Project Name 
Customer Number23333-23
ePlanReviewNo
Description
Complete HVAC Installation: Install new HVAC system
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Pressure Test8/7/20208/10/20208/10/2020APASS
DetailsBen Livingston
Phone #: ###-#### Inspection requested via web by Debbie Marino
-60lb,20lb,piping
Pressure Test8/7/20208/7/20208/7/2020PFAIL
DetailsBen Livingston
pressure test on underground gas lines Phone #: ###-#### Inspection requested via web by Debbie Marino
- need to tape first 90 all 3 locations
Pressure Test8/5/20208/6/20208/6/2020AFAIL
DetailsBen Livingston
Need pressure test on underground gas lines Phone #: ###-#### Inspection requested via web by Debbie Marino
- black pipe in 3 locations needs tape where it is underground, 20,60 lb okay
Rough-in8/3/20208/3/20208/3/2020PPASS
DetailsBen Livingston
Fireplace flue Phone #: ###-#### Inspection requested via web by Debbie Marino
Rough-in7/31/20207/31/20207/31/2020PCANC
DetailsBen Livingston
FP Flue test Phone #: ###-#### Inspection requested via web by Debbie Marino
- canc per request
Rough-in7/28/20207/29/20207/29/2020AFAIL
DetailsBen Livingston
FP Flue inspection Phone #: ###-#### Inspection requested via web by Debbie Marino
- firestop around flues have open gaps
- ducts on either side of fireplace need tobe riged pipe till they pass through fire stop
Rough-in7/23/20207/24/20207/24/2020APASS
DetailsBen Livingston
Please call 2089418059 when you are on your way Phone #: ###-#### Inspection requested via web by Debbie Marino
Rough-in7/21/20207/21/20207/21/2020PFAIL
DetailsBen Livingston
Phone #: ###-#### Inspection requested via web by Debbie Marino
- condensate piping needs tobe 3/4 pvc at the point of first possible grade correction not made
Rough-in7/14/20207/15/20207/15/2020PFAIL
DetailsBen Livingston
Phone #: ###-#### Inspection requested via web by Debbie Marino
- condensate piping needs tobe 3/4 pvc at the point of first possible grade
Pressure Test7/14/20207/15/20207/15/2020PPASS
DetailsBen Livingston
Phone #: ###-#### Inspection requested via web by Debbie Marino
- 60lb,5lb x5
Pressure Test7/14/20207/14/20207/14/2020PFAIL
DetailsBen Livingston
Phone #: ###-#### Inspection requested via web by Debbie Marino
- test at zero
Rough-in7/14/20207/14/20207/14/2020PFAIL
DetailsBen Livingston
Phone #: ###-#### Inspection requested via web by Debbie Marino
- condensate piping needs tobe 3/4 pvc at the point of first possible grade
- need nail plates to protect linesets and condensate piping in wall closer that 1 1/2"
- supply in basement feeding bed rooms above is going tobe crushed by data cable when its drywalled
- 5lb flue x5 okay
Pressure Test7/13/20207/14/20207/14/2020ACANC
DetailsBen Livingston
Phone #: ###-#### >> Inspection requested via web by Debbie Marino Inspection cancelled from web by: Debbie Marino
Rough-in7/13/20207/14/20207/14/2020ACANC
DetailsBen Livingston
Phone #: ###-#### >> Inspection requested via web by Debbie Marino Inspection cancelled from web by: Debbie Marino