Information based on query as of Tuesday, June 25, 2024.
Permit Information
Permit NumberMEC20-01605
StatusIssued
Name AIR CARE LLC
Site Address 1013 S VISTA AVE
Project Name 
Customer NumberC-1373
ePlanReviewNo
Description
Alteration: Remove existing ductwork, install new ductwork, new grilles and registers. Adding gasline to heat pump.
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Pressure Test5/19/20205/19/20205/19/2020PPASS
DetailsJack Reynolds
Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN
- 60lb gas test ok
- tagged meter location
Rough-in5/19/20205/19/20205/19/2020PPASS
DetailsJack Reynolds
Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN
- R/I ok
Pressure Test5/18/20205/19/20205/19/2020AFAIL
DetailsJack Reynolds
Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN
- 60lb gas test fail
- pressure test gas line with two valves and a open tee between them at meter or disconnect gas line from meter and cap
Pressure Test5/14/20205/15/20205/15/2020ANR
DetailsJack Reynolds
Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN
Pressure Test5/13/20205/14/20205/14/2020PFAIL
DetailsJack Reynolds
Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN

- 60lb gas test fail
- need to adjust permit details to reflect work being done for a R/I pass.
Rough-in5/12/20205/12/20205/12/2020PFAIL
DetailsJack Reynolds
Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN
- need gas pressure test
- CSST gas line needs proper nail plates installed
- verify what gas pressure will be supplied from meter