Rough-in | 7/28/2020 | 7/29/2020 | 7/29/2020 | A | PASS |
Chad Schwendiman
|
|
|
Please call Brandon ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks
|
Rough-in | 7/28/2020 | 7/28/2020 | 7/28/2020 | P | FAIL |
Chad Schwendiman
|
|
|
Brandon ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks - Still need plumbing vent moved to provide clear access to furnace platform, Need furnace platform extended to attic access opening.
|
Rough-in | 7/24/2020 | 7/24/2020 | 7/24/2020 | P | FAIL |
Brian Scoles
|
|
|
Phone #: ###-#### Inspection requested via web by Arielle Hendricks 1- need city approved man j onsite 2- seal all spot welds on supply boots 3- need ladder provided to access furnace in attic 4- OSA can ot terminate to roof 5- access to attic needs 24" wide access to platform with 30" clearance to front of furnace and unobstructed has plumbing vent in way 6- insulation on supply main needs taped in multiple locations where insulation is showing 7- primary condensate has trap in it needs 1/4" per foot grade from coil to outside and nail plates at top plate
correction notice posted
DO NOT COVER
|
Pressure Test | 7/24/2020 | 7/24/2020 | 7/24/2020 | P | PASS |
Brian Scoles
|
|
|
Phone #: ###-#### Inspection requested via web by Arielle Hendricks- 20lb gas pass tagged meter location
|
Final | 7/24/2020 | 7/24/2020 | 7/24/2020 | P | CANC |
Brian Scoles
|
|
|
Phone #: ###-#### >> Inspection requested via web by Arielle Hendricks Inspection cancelled from web by: Arielle Hendricks
|
Final | 6/10/2020 | 6/11/2020 | 6/11/2020 | P | NR |
Ben Livingston
|
|
|
Please call Chuck on your way - ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks
|