Rough-in | 7/15/2020 | 7/15/2020 | 7/15/2020 | P | PASS |
Brian Scoles
|
|
|
Corrections have been made Phone #: ###-#### Inspection requested via web by Oleg Chervak- R/I ok
|
Rough-in | 7/10/2020 | 7/10/2020 | 7/10/2020 | P | FAIL |
Brian Scoles
|
|
|
Phone #: ###-#### Inspection requested via web by Oleg Chervak- access platform still needs installed 24 inches wide with 30x30 access in front- went over with Andrey
|
Rough-in | 7/6/2020 | 7/7/2020 | 7/7/2020 | A | FAIL |
Brian Scoles
|
|
|
CORRECTIONS COMPLETED AND READY FOR REINSPECT Phone #: ###-#### Inspection requested via web by Oleg Chervak- item 1, 2 and 4 still need corrections addressed- reinspection fee issued
|
Pressure Test | 7/6/2020 | 7/7/2020 | 7/7/2020 | A | PASS |
Brian Scoles
|
|
|
CORRECTIONS COMPLETED AND READY FOR REINSPECT Phone #: ###-#### Inspection requested via web by Oleg Chervak- 20lb gas pass tagged meter location
|
Rough-in | 7/6/2020 | 7/6/2020 | 7/6/2020 | P | CANC |
Brian Scoles
|
|
|
CORRECTIONS HAVE BEEN MADE. PLEASE REINSPECT Phone #: ###-#### >> Inspection requested via web by Oleg Chervak Inspection cancelled from web by: Oleg Chervak
|
Rough-in | 6/29/2020 | 6/30/2020 | 6/30/2020 | P | FAIL |
Brian Scoles
|
|
|
manual j will be on site corrections made please reinspect Phone #: ###-#### Inspection requested via web by Oleg Chervak 1- dryer duct smashed 3rd floor notch bigger and repace duct 2- need access platform in attic to front of mini split and 30" clearance and unobstructed 3- need engineers approval for gas piping thru lel beam in garage 4- need transfers to laundry and bathroom 5- gas gauge wont zero out 6- fireplace needs uncovered and instructions available
notice left
|
Pressure Test | 6/29/2020 | 6/30/2020 | 6/30/2020 | P | FAIL |
Brian Scoles
|
|
|
new gadge installed Phone #: ###-#### Inspection requested via web by Oleg Chervak- gauge doesnt zero out
|
Rough-in | 6/26/2020 | 6/29/2020 | 6/29/2020 | P | CANC |
Brian Scoles
|
|
|
DO FIREPLACE ROUGH IN INSPECTIONS FOR THE WHOLE BUILDING FOR US, FOR GOT TO INCLUDE THAT INTO THE NOTES Phone #: ###-#### >> Inspection requested via web by Oleg Chervak Inspection cancelled from web by: Oleg Chervak
|
Pressure Test | 6/26/2020 | 6/26/2020 | 6/26/2020 | P | FAIL |
Brian Scoles
|
|
|
Phone #: ###-#### Inspection requested via web by Oleg Chervak- gauge wont zero out
|
Rough-in | 6/26/2020 | 6/26/2020 | 6/26/2020 | P | CANC |
Brian Scoles
|
|
|
Phone #: ###-#### >> Inspection requested via web by Oleg Chervak Inspection cancelled from web by: Oleg Chervak
|
Conference | 6/23/2020 | 6/23/2020 | 6/23/2020 | P | DONE |
Brian Scoles
|
|
|
PLEASE CONTACT ANDREY AND WALKTHOUGH THIS PROJECT WITH HIM. WE WANT TO BE SURE THAT WE ARE CODE COMPLIANT, THANK YOU. Phone #: ###-#### Inspection requested via web by Oleg Chervak- discussed pvc drains- condensers middle units will need drain/pan underneath and freeze protected on decks- exhaust fans 1st floor needs to be 3 feet from property line- talked with Alex about this onsite
|