Rough-in | 7/15/2020 | 7/15/2020 | 7/15/2020 | P | PASS |
Brian Scoles
|
|
|
Correction made Phone #: ###-#### Inspection requested via web by Oleg Chervak- R/I ok
|
Rough-in | 7/10/2020 | 7/10/2020 | 7/10/2020 | P | FAIL |
Brian Scoles
|
|
|
Phone #: ###-#### Inspection requested via web by Oleg Chervak- access platform stills installed 24 inches wide and 30x30 in front of unit- need framing around exhaust completed- went over oinsite with Andrey
|
Rough-in | 7/6/2020 | 7/7/2020 | 7/7/2020 | A | FAIL |
Brian Scoles
|
|
|
CORRECTIONS COMPLETED AS REQUESTED PLEASE REINSPECT Phone #: ###-#### Inspection requested via web by Oleg Chervak- items 1 3 7 and 8 still need corrections addressed- reinspection fee issued
|
Pressure Test | 7/6/2020 | 7/7/2020 | 7/7/2020 | A | PASS |
Brian Scoles
|
|
|
GADGE REPLACED PLEASE REINSPECT Phone #: ###-#### Inspection requested via web by Oleg Chervak- 20lb gas pass tagged meter location
|
Rough-in | 6/29/2020 | 6/30/2020 | 6/30/2020 | P | FAIL |
Brian Scoles
|
|
|
ready for inspection Phone #: ###-#### Inspection requested via web by Oleg Cherva 1- need access platform in attic to mini split with 30" clearance to front and unobstructe 2- fireplace needs uncovered and instructions available 3- transfer laundry and bathroom 4- range duct needs completed below framinf 5- gas gauge wont zero out 6- missing supply above stairs 3rd floor 7- need framing completed around exhaust in closet 8- condenser need drain ran for balcony can not discharge on balcony
left notice
|
Pressure Test | 6/29/2020 | 6/30/2020 | 6/30/2020 | P | FAIL |
Brian Scoles
|
|
|
ready for inspection Phone #: ###-#### Inspection requested via web by Oleg Chervak- gauge wont zero out
|
Rough-in | 6/26/2020 | 6/26/2020 | 6/26/2020 | P | FAIL |
Brian Scoles
|
|
|
Phone #: ###-#### Inspection requested via web by Oleg Chervak- need city approved man j onsite to do inspection
|
Pressure Test | 6/26/2020 | 6/26/2020 | 6/26/2020 | P | FAIL |
Brian Scoles
|
|
|
Phone #: ###-#### Inspection requested via web by Oleg Chervak- gauge wont zero out
|