Final | 8/5/2020 | 8/5/2020 | 8/5/2020 | P | PASS |
Brian Scoles
|
|
|
90 percent furnace in bedroom closet combustion air and flue 2 piped to outside- a/c coil co locking caps ok via virtual video-
|
Pressure Test | 8/5/2020 | 8/5/2020 | 8/5/2020 | P | PASS |
Brian Scoles
|
|
|
20lb gas pass tagged meter location- 5lb flue test via virtual video onsite with installer
|
Pressure Test | 8/4/2020 | 8/5/2020 | 8/5/2020 | A | FAIL |
Brian Scoles
|
|
|
Re inspection- Gas pressure test Phone #: ###-#### Inspection requested via web by Kelly Martin- gauge wouldnt zero out- Willie tracking one down
|
Final | 7/31/2020 | 8/3/2020 | 8/3/2020 | A | FAIL |
Brian Scoles
|
|
|
Final and Gas Pressure test. Please contact homeowners with ETA. Jason ###-#### his wife''s number is ###-####. Thank You! Phone #: ###-#### Inspection requested via web by Kelly Martin- low pressure test on gas line needs 30lb gauge max and tested at 20psi has 100lb gauge- retest- exterior lineset and condensate drain need weather tight/rodent proof thru crawl vent- due to COVID 19 city of Boise has suspended in occupied home til later date and no date set yet- virtual video with contractor onsite is acceptable-
|