Permit Number | MIS03-00044 |
Status | Finaled |
Name |
MOTOSPORTS LLC
|
Site Address |
6481 W OVERLAND RD
|
Project Name | |
Customer Number | |
ePlanReview | |
Description |
(MOTOSPORTS LLC) Application for inspection to determine requirements for issuance of a Certificate of Occupancy for an existing 8,050 sq. ft. building in accordance with Resolution 13533. Tenant use is motorcycle repair garage, storage warehouse, retail and service/business. Existing one-hour fire barrier wall and door between repair garage and service/business area per previous code and permits. (One-hour fire barrier separation to remain intact and be verified.) No racking exceeding 8' in height allowed in the space. Any hazardous materials in space must be under maximum allowable quantities per IBC Table 307.7(1). East exterior wall is existing one-hour fire rated per location on property with no openings allowed. A portion of the West exterior wall is existing one-hour fire rated per location on property with unprotected openings allowed. Nonseparated uses per IBC Section 302.3.2 other than repair garage separation still required. This permit does not authorize any work in the space. This building is NOT fire sprinklered. Previous use was a detail/minor repair garage under tenant of "My Nu Car". JCB
|