Permit Information
Permit NumberMIS10-00071
StatusFinaled
Name S-SIXTEEN LIMITED PARTNERSHIP
Site Address 6801 S FEDERAL WAY
Project NameComplaint
Customer Number 
ePlanReview 
Description
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
MIS-Aging Inspection7/1/20107/1/20107/1/2010PPASS
DetailsBill VanDegrift
defr from 301
DOC - Permit Finaled7/1/20107/1/20107/1/2010PPASS
DetailsBill VanDegrift
defr from 301 corrections made with a plumbing permit
MIS-Aging Inspection6/30/20106/30/20107/1/2010 DEFR
DetailsJim Storey
to 330
PLM-Final3/24/20104/30/20104/30/2010ANR
DetailsBill VanDegrift
contractor will call when ready
PLM-Conference4/5/20104/5/20104/5/2010APASS
DetailsBill VanDegrift
met with Bill from meridian plumbing about cross connection upgrades.
PLM-Conference3/24/20103/24/20103/24/2010PFAIL
DetailsBill VanDegrift
created this mis to track required cross connection control compliance. dropped off a correction notice at Perkins. corrections were originally addressed on a survey by United water and plumbing inspector from 7/14/09, associated with PLM09-01103.
*CORRECNTION NOTICE*
On 7/14/09 a cross connection survey was preformed at the above address with United Water. The following is a list of measures required to bring this building into compliance. Action must be taken with in 30 days. (1) watrer softener drain requires an air gap. (2) chemical station at the mop sink requires a seperate water supply. (3) R.P. required on the ice mechine upstream of the filter. (4) dish washer requires an R.P. (5) juicer requires a DCVA. (6) Hot Cocoa maker requires a DCVA (7) R.P. required on the water supply to the coffee maker, hot water dispensor and Ice tea maker. All the above is to be done by a licensed plumbing contractor, permitted and called in for inspection.