Final | 3/12/2001 | 3/12/2001 | 3/12/2001 | P | PASS |
Bill VanDegrift
|
|
|
call to meet there ###-####
|
Final | 1/17/2001 | 1/17/2001 | 1/17/2001 | P | FAIL |
Bill VanDegrift
|
|
|
###-#### call first ammend permit to reflect interior fixtures, replumb bathroom waste so vents are above trap, 2 " min waste for waher, extendvent thru roof, pipe 3/4 from main shutoff to existing and a 3/4 branch to the water heater off that pick up the kitchen sink cold, 3/4 from the water heater to the existing with a 1/2" branch to the kitchen, lower kitchen sink trap to be below vent, pipe t&p drain to exterior with out traps 3/4", 3/4" valve required at the waterheater, plug sewer at manhole and test waste to floor level. water and sewer services installed without an ispection if the test holds I'll assume it's ok the water connection in the crawl seems ok and will assume the joint at the meter is the same. 1/17/2001 2:18:11 PM
|