Final | 8/14/2001 | 8/15/2001 | 8/15/2001 | A | PASS |
Jim Johnson
|
|
|
Scheduled by a contractor via Hello! on 08/14/2001 at 16:15:49. Contact: ###-####.
|
PLM-Aging Inspection | 5/23/2001 | 5/23/2001 | 5/23/2001 | | PART |
Jim Johnson
|
|
|
rough-in inspection done still working on project permit expires 8-14-2001 5/23/2001 11:43:36 AM
|
Plumbing Rough-in | 2/16/2001 | 2/16/2001 | 2/16/2001 | A | PASS |
Jim Johnson
|
|
|
Scheduled by a contractor via Hello! on 02/16/2001 at 07:21:28. Contact: ###-####.
|
Plumbing Rough-in | 2/15/2001 | 2/15/2001 | 2/15/2001 | P | FAIL |
Jim Johnson
|
|
|
jim ###-#### r/i insp need cleanout in vertical portion of foot vent . lav above entry stairs need to be 6-inches above flood level rim of fixture. nail plates by washer box water and drain. need to support main water service under crawl 2/15/2001 2:53:49 PM
|