Final | 8/28/2002 | 8/29/2002 | 8/29/2002 | A | FAIL |
Bill VanDegrift
|
|
|
###-#### test dcva, provide access to rear of the project 8/29/2002 8:33:29 AM
|
Final | 4/25/2002 | 4/25/2002 | 4/25/2002 | P | FAIL |
Bill VanDegrift
|
|
|
###-#### test dcva, remove flex from lav waste, install c.o. covers, turn on water to shower, work to be done by a licensed plumber, set trim on the back 1/2 of the project. 4/25/2002 2:02:23 PM
|
Plumbing Rough-in | 12/28/2001 | 12/31/2001 | 12/31/2001 | A | PASS |
Bill VanDegrift
|
|
|
NICHOLE OR JOHN ###-#### wii provide an access to unions at shower valve, ri ok 12/31/2001 9:27:56 AM
|
Plumbing Rough-in | 12/13/2001 | 12/14/2001 | 12/14/2001 | P | FAIL |
Bill VanDegrift
|
|
|
Scheduled by a contractor via Hello! on 12/13/2001 at 16:54:06. Contact: ###-####. provide approved plans, pressure ballance valves required, shower drain in basement backgraded, flexable rubber drainage fittings prohibitted, die electric unions must be exposed, premis protection and thermol expantion protection will be required, r/i incomplete. 12/14/2001 2:58:37 PM
|