Final | 3/26/2002 | 3/26/2002 | 3/26/2002 | P | PASS |
Jim Johnson
|
|
|
###-#### 3/26/2002 3:04:48 PM
|
Final | 3/25/2002 | 3/25/2002 | 3/25/2002 | P | PART |
Jim Johnson
|
|
|
BOB ###-#### need to provide for thermal expansion need to provide protective cover,s for handdicapp lav water and waste drain called Bob plumbing contractor will recall when ready 3/25/2002 5:06:09 PM
|
Plumbing Rough-in | 1/31/2002 | 1/31/2002 | 1/31/2002 | P | PASS |
Jim Johnson
|
|
|
Scheduled by Inspector: 360 On 1/31/2002 2:24:51 PM
|
Plumbing Rough-in | 1/30/2002 | 1/30/2002 | 1/30/2002 | P | FAIL |
Jim Johnson
|
|
|
JIM , PLEASE CALL RON AT ###-#### BEFORE YOU GO OUT SO HE CAN MEET YOU THERE TO LET YOU IN ... abs drain lines need to be supported every four feet support pex piping every 32 inches also need some additional cleanout,s installed. cap off all abandon drain lines 1/30/2002 3:48:24 PM
|