Final | 3/1/2004 | 3/1/2004 | 3/1/2004 | P | PASS |
Gary Ziegler
|
|
|
kevin; Phone #: ###-#### Internet Inspection Request from: Barbara Moore
|
Plumbing Rough-in | 1/23/2004 | 1/26/2004 | 1/26/2004 | A | PASS |
Gary Ziegler
|
|
|
lisa -- ###-####- -re-insp
|
Plumbing Rough-in | 1/16/2004 | 1/21/2004 | 1/21/2004 | A | FAIL |
Ron Ginner
|
|
|
LISA; Phone #: ###-#### Internet Inspection Request from: Darla Downs 1. need base of stack cleanout and another one in three inch line due to >135 degree change of direction 2. no test on dwv or water 3. need mid story guides on water lines to upstairs 1/21/2004 11:21:40 AM
|