Final | 10/2/2007 | 10/2/2007 | 10/2/2007 | P | PASS |
Gerry Varner
|
|
|
adam - please call for access Phone #: ###-#### FINAL FOR FIRST FLOOR ONLY. he will permit upper fixtures again when upstairs is finished.
|
Plumbing Rough-in | 2/14/2007 | 2/14/2007 | 2/14/2007 | P | PASS |
Jim Johnson
|
|
|
adam ; Phone #: ###-#### Internet Inspection Request from: Patricia Smith
|
Plumbing Rough-in | 2/12/2007 | 2/12/2007 | 2/12/2007 | P | FAIL |
Eric Strole
|
|
|
adam; Phone #: ###-#### Internet Inspection Request from: Victoria Beall-missing nailplates, cannot use transition glue inside building, support pex every 32"- support tub spout on upstairs tub, fernco's not approved in crawl on 3" horizontal drain, need to roll y on island sink vent.
|
Water and/or Sewer | 11/28/2006 | 11/28/2006 | 11/28/2006 | P | PASS |
Bill VanDegrift
|
|
|
sewer and water service ok
|