Final | 11/9/2006 | 11/9/2006 | 11/9/2006 | P | PASS |
Jim Johnson
|
|
|
randy; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles
|
Final | 11/7/2006 | 11/8/2006 | 11/8/2006 | A | PART |
Jim Johnson
|
|
|
randy ; Phone #: ###-#### Internet Inspection Request from: Patricia Smith need to correct all leak,s and turn water in to all fixture,s need to lower double check to five foot above floor or grade or provide an approved platform as per upc2003 603.3.4 called contractor will recall when ready
|
Final | 11/3/2006 | 11/3/2006 | 11/3/2006 | P | PART |
Bill VanDegrift
|
|
|
randy - note - please call 1 hr prior to inspection -- partial ; Phone #: ###-#### Internet Inspection Request from: Patricia Smith temp occ ok
|
Other | 11/1/2006 | 11/1/2006 | 11/1/2006 | A | DONE |
Eric Strole
|
|
|
this was a conferance-talked with mike jordan- plumb as per approved plans- install dbcv on building supply with exspantion tank-bring t&p up to code-need tempered water on all public lavs.
|