Final | 7/24/2007 | 7/25/2007 | 7/25/2007 | A | PASS |
Daryl Spivey
|
|
|
Jim Ellison is the field contact. Phone #: ###-#### Internet Inspection Request from: Heidi Mallet
|
Other | 7/17/2007 | 7/24/2007 | 7/24/2007 | A | FAIL |
Bill VanDegrift
|
|
|
espresso needs an r.p., ice tea needs a dcva. test all the new back flow preventers
|
Final | 7/18/2007 | 7/19/2007 | 7/19/2007 | A | PART |
Bill VanDegrift
|
|
|
Colin Libby is the field contact. Phone #: ###-#### Internet Inspection Request from: Heidi Mallet air gap ice bin drains in the kitchen. air gap water softener flush line. r.p. requied on the galss sterlizer in bar. set all equipment, coffee makers etc. temp occ ok.
|
Other | 7/16/2007 | 7/17/2007 | 7/17/2007 | A | CANC |
Bill VanDegrift
|
|
|
10ish
|
Other | 7/13/2007 | 7/17/2007 | 7/17/2007 | A | PEND |
Daryl Spivey
|
|
|
10 am left correction notice on problems found on 7/13....health dept appt. was xled and rescheduled for 7/19......ds
|
Final | 7/12/2007 | 7/13/2007 | 7/13/2007 | A | FAIL |
Daryl Spivey
|
|
|
Colin Libby is the field contact. Phone #: ###-#### Internet Inspection Request from: Heidi Mallet Trap sinks more than 5 feet from indirect waste point, airgap needed also on multiple drains, all fixtures need to be set, disconnect rinse sink from direct connect, air gap ice bin drains, 2 pumps for ejector, schedule walk thru with plumber and possibly bill thompson....ds
|
Plumbing Rough-in | 5/8/2007 | 5/9/2007 | 5/9/2007 | A | PASS |
Daryl Spivey
|
|
|
Sean Hart is the field contact. Phone #: ###-#### Internet Inspection Request from: Heidi Mallet
|
Plumbing Rough-in | 4/26/2007 | 4/26/2007 | 4/26/2007 | P | PART |
Bill VanDegrift
|
|
|
scott Note: partial r/i; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles everything except the lavs
|