Permit Information
Permit NumberPLM07-01974
StatusFinaled
Name BUSS MECHANICAL SERVICES INC
Site Address 8055 W GODDARD RD
Project Name 
Customer Number 
ePlanReview 
Description
Plumbing Permit - Alteration: REMODEL CLASSROOM, PLUMBING, AND FIXTURES
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final10/15/200710/16/200710/16/2007APASS
DetailsEric Strole
Final9/14/20079/14/20079/14/2007PPART
DetailsEric Strole
JOB CONTACT IS CHRIS BUSS Phone #: ###-#### Internet Inspection Request from: ADAM WARR-buss final pass, still need letter from boise school district.
Final8/22/20078/23/20078/23/2007PCANC
DetailsEric Strole
JOB CONTACT IS CHRIS BUSS Phone #: ###-#### Internet Inspection Request from: KYLIE HICKS Inspection cancelled from web by: JENN STALEY
Final8/15/20078/16/20078/16/2007APART
DetailsEric Strole
JOB CONTACT IS CHRIS BUSS Phone #: ###-#### Internet Inspection Request from: KYLIE HICKS-temp ok, waiting to here from school district.
Other8/16/20078/16/20078/16/2007PPASS
DetailsBill VanDegrift
Final8/14/20078/15/20078/15/2007AFAIL
DetailsEric Strole
JOB CONTACT IS CHRIS BUSS Phone #: ###-#### Internet Inspection Request from: ADAM WARR-no final till last correction notice is addressed.need to change out pvc female adapters on drains under lab sinks to approved material, need spec sheet on traps for lab sinks, need to support traps.
Plumbing Rough-in7/17/20077/18/20077/18/2007APASS
DetailsEric Strole
CONTACT: CHRIS BUSS Phone #: ###-#### Internet Inspection Request from: JENN STALEY-this was the water tie in in mech room, rpba's need tested & certified & labeled & label all non potable water. need to add unions on rpba's, will check on final.
Plumbing Rough-in7/12/20077/12/20077/12/2007APASS
DetailsEric Strole
r/i pass, mech room still needs finished.
Other7/11/20077/12/20077/12/2007ADONE
DetailsEric Strole
this was a conferance with bill wittkopf with boise schools & bill thomson, upgrades on backflow protection is being started in schools.
Other6/26/20076/27/20076/27/2007APART
DetailsEric Strole
add to first inspection note-need to isolate lab sinks in rooms 104,110,109,350,213,106,208,212 & 300 with rpba's-eye wash in kitchen needs spill proof vacuum breaker,eye wash in all janitor rooms need pvb's,kitchen area in room s11 needs rpba on water cooled condensers.
Other6/26/20076/26/20076/26/2007PDONE
DetailsEric Strole
this was a conferance with thomson & criss wiyh buss on upgrades of school.need dbcv on service-need to isolate boiler equipment with a rpba-need to isolate ejector primer with a rpba-need hvb's on mop sink in boiler room-need rpba's on all soap dispensers in mop sink rooms.
Plumbing Rough-in6/25/20076/26/20076/26/2007APART
DetailsEric Strole
JOB CONTACT IS CHRIS BUSS, ASKED FOR INSPECTION AS EARLY IN MORNING AS POSSIBLE Phone #: ###-#### Internet Inspection Request from: KYLIE HICKS-water & dwv for wall inspection 0n sinks only pass.