Information based on query as of Thursday, July 18, 2024.
Permit Information
Permit NumberPLM08-01567
StatusFinaled
Name BUSS MECHANICAL SERVICES INC
Site Address 10700 W USTICK RD
Project Name 
Customer Number 
ePlanReview 
Description
Plumbing Permit - New: waste & vent, water gas fixtures
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final12/5/200812/8/200812/8/2008APASS
DetailsEric Strole
Final12/4/200812/5/200812/5/2008PCANC
DetailsEric Strole
JOB CONTACT IS DAVE WINCHESTER Phone #: ###-#### Internet Inspection Request from: ADAM WARR
Final10/31/200811/3/200811/3/2008APART
DetailsEric Strole
contact is Dave ###-#### Phone #: ###-#### Internet Inspection Request from: LENNIE BUSS-cut toe kick out of cabinet in front of floor sink in florist & make water tight. need rpba on steamer in fish market, need rpba on chemical dispensors in fisht, meat , deli & produce prep area. need rpba on sterilox in produce prep area. r.o. in pharmacy needs to have drain indirect & have dbca installed. all backflow devices need to be upstream of any filters. all backflow devices need tested & certified.
Final9/11/20089/12/20089/12/2008AFAIL
DetailsEric Strole
partial final for flower & starbucks-(flower area( need to make area around & under cabinet by floor sink water tight. (starbucks) need to install rpba upstream of R.O. system. esspresso machine needs to be isolated with a rpba. coffee maker needs to be isolated with a dbca. ice maker needs to be isolated with a dbca. glass cleaner hooked up to faucet needs it's own water supply isolated with a rpba or delete.
Groundwork9/11/20089/12/20089/12/2008APART
DetailsEric Strole
meat & seafood-ground work in meat & seafood pass.
Groundwork9/11/20089/11/20089/11/2008PPART
DetailsEric Strole
Contact David or Henry ###-#### Phone #: ###-#### Internet Inspection Request from: James Stanford-need to pull vent off downstream of upper most flr sink & reduce tailpiece to 2" on combination waste & vent.
Groundwork8/12/20088/13/20088/13/2008APART
DetailsEric Strole
CONTACT IS DAVE WINCHESTER Phone #: ###-#### Internet Inspection Request from: LENNIE BUSS-ground work for hub drains for isle 8 pass.
Groundwork8/7/20088/8/20088/8/2008APART
DetailsEric Strole
reinspection-ground work & inwall rough-in for flr sink & hub drain in front of video rental area pass.
Groundwork8/6/20088/7/20088/7/2008AFAIL
DetailsEric Strole
CONTACT IS DAVE WINCHESTER Phone #: ###-#### Internet Inspection Request from: LENNIE BUSS-dwv test failed.
Groundwork7/31/20088/1/20088/1/2008APASS
DetailsDaryl Spivey
PLEASE USE DAVE W. FOR CONTACT, THANK YOU. Phone #: ###-#### Internet Inspection Request from: JENN STALEY
Groundwork7/18/20087/18/20087/18/2008APART
DetailsEric Strole
JOB CONTACT IS DAVE WINCHESTER Phone #: ###-#### Internet Inspection Request from: ADAM WARR-ground work in cooler area pass, except tie-in from abs to pvc. cannot glue abs to pvc inside building.winchester will have picture of fix on next inspection.
Groundwork7/14/20087/14/20087/14/2008APASS
DetailsEric Strole
JOB CONTACT IS DAVID WINCHESTER Phone #: ###-#### Internet Inspection Request from: ADAM WARR-service sink in service area pass.