Final | 12/5/2008 | 12/8/2008 | 12/8/2008 | A | PASS |
Eric Strole
|
|
|
|
Final | 12/4/2008 | 12/5/2008 | 12/5/2008 | P | CANC |
Eric Strole
|
|
|
JOB CONTACT IS DAVE WINCHESTER Phone #: ###-#### Internet Inspection Request from: ADAM WARR
|
Final | 10/31/2008 | 11/3/2008 | 11/3/2008 | A | PART |
Eric Strole
|
|
|
contact is Dave ###-#### Phone #: ###-#### Internet Inspection Request from: LENNIE BUSS-cut toe kick out of cabinet in front of floor sink in florist & make water tight. need rpba on steamer in fish market, need rpba on chemical dispensors in fisht, meat , deli & produce prep area. need rpba on sterilox in produce prep area. r.o. in pharmacy needs to have drain indirect & have dbca installed. all backflow devices need to be upstream of any filters. all backflow devices need tested & certified.
|
Final | 9/11/2008 | 9/12/2008 | 9/12/2008 | A | FAIL |
Eric Strole
|
|
|
partial final for flower & starbucks-(flower area( need to make area around & under cabinet by floor sink water tight. (starbucks) need to install rpba upstream of R.O. system. esspresso machine needs to be isolated with a rpba. coffee maker needs to be isolated with a dbca. ice maker needs to be isolated with a dbca. glass cleaner hooked up to faucet needs it's own water supply isolated with a rpba or delete.
|
Groundwork | 9/11/2008 | 9/12/2008 | 9/12/2008 | A | PART |
Eric Strole
|
|
|
meat & seafood-ground work in meat & seafood pass.
|
Groundwork | 9/11/2008 | 9/11/2008 | 9/11/2008 | P | PART |
Eric Strole
|
|
|
Contact David or Henry ###-#### Phone #: ###-#### Internet Inspection Request from: James Stanford-need to pull vent off downstream of upper most flr sink & reduce tailpiece to 2" on combination waste & vent.
|
Groundwork | 8/12/2008 | 8/13/2008 | 8/13/2008 | A | PART |
Eric Strole
|
|
|
CONTACT IS DAVE WINCHESTER Phone #: ###-#### Internet Inspection Request from: LENNIE BUSS-ground work for hub drains for isle 8 pass.
|
Groundwork | 8/7/2008 | 8/8/2008 | 8/8/2008 | A | PART |
Eric Strole
|
|
|
reinspection-ground work & inwall rough-in for flr sink & hub drain in front of video rental area pass.
|
Groundwork | 8/6/2008 | 8/7/2008 | 8/7/2008 | A | FAIL |
Eric Strole
|
|
|
CONTACT IS DAVE WINCHESTER Phone #: ###-#### Internet Inspection Request from: LENNIE BUSS-dwv test failed.
|
Groundwork | 7/31/2008 | 8/1/2008 | 8/1/2008 | A | PASS |
Daryl Spivey
|
|
|
PLEASE USE DAVE W. FOR CONTACT, THANK YOU. Phone #: ###-#### Internet Inspection Request from: JENN STALEY
|
Groundwork | 7/18/2008 | 7/18/2008 | 7/18/2008 | A | PART |
Eric Strole
|
|
|
JOB CONTACT IS DAVE WINCHESTER Phone #: ###-#### Internet Inspection Request from: ADAM WARR-ground work in cooler area pass, except tie-in from abs to pvc. cannot glue abs to pvc inside building.winchester will have picture of fix on next inspection.
|
Groundwork | 7/14/2008 | 7/14/2008 | 7/14/2008 | A | PASS |
Eric Strole
|
|
|
JOB CONTACT IS DAVID WINCHESTER Phone #: ###-#### Internet Inspection Request from: ADAM WARR-service sink in service area pass.
|