PLM-Aging Inspection | 4/16/2012 | 4/16/2012 | 4/16/2012 | | PASS |
Jim Johnson
|
|
|
|
DOC - Permit Expired | 4/16/2012 | 4/16/2012 | 4/16/2012 | A | PASS |
Jim Johnson
|
|
|
|
PLM-Aging Inspection | 1/16/2012 | 1/16/2012 | 1/17/2012 | | PASS |
Jim Johnson
|
|
|
|
PLM-Aging Inspection | 10/13/2011 | 10/13/2011 | 10/13/2011 | | PASS |
Jim Johnson
|
|
|
|
PLM-Aging Inspection | 7/14/2011 | 7/14/2011 | 7/19/2011 | | PASS |
Jim Johnson
|
|
|
|
Plumbing Rough-in | 4/14/2011 | 4/15/2011 | 4/15/2011 | A | PASS |
Jim Johnson
|
|
|
Scott Phone #: ###-####
|
Plumbing Rough-in | 4/11/2011 | 4/11/2011 | 4/11/2011 | P | CANC |
Jim Johnson
|
|
|
thomas Phone #: ###-####
|
Plumbing Rough-in | 4/8/2011 | 4/11/2011 | 4/11/2011 | A | FAIL |
Jim Johnson
|
|
|
need to uncover water line for inspection lower water line to 36 inches below finish grade call for in spection when ready need to install vent pipes in accordance with the requirments of chapter 9 upc 2003 need to update permit to include all new plumbing for water and D W V piping to new and existing fixtures
|
Plumbing Rough-in | 4/8/2011 | 4/8/2011 | 4/8/2011 | P | CANC |
Jim Johnson
|
|
|
Bill Phone #: ###-####
|
Plumbing Rough-in | 3/23/2011 | 3/24/2011 | 3/24/2011 | A | PASS |
Jim Johnson
|
|
|
Scott Phone #: ###-#### inspection for groundwork only at this time
|
Groundwork | 3/23/2011 | 3/23/2011 | 3/23/2011 | P | FAIL |
Jim Johnson
|
|
|
scott Phone #: ###-#### as per 2003 upc 710.1 need an approved type backwater valve in new basement D W V ground work talked to contractor will recall when ready
|