Final | 4/12/2012 | 4/13/2012 | 4/13/2012 | A | PASS |
Eric Strole
|
|
|
Lock box at back door code 1094 any ?s call Jimmy @###-#### thank you Phone #: ###-#### >> Inspection requested via web by James Walsh
|
Plumbing Rough-in | 3/8/2012 | 3/9/2012 | 3/9/2012 | A | PASS |
Jim Johnson
|
|
|
Phone #: ###-#### >> Inspection requested via web by James Walsh
|
Plumbing Rough-in | 3/7/2012 | 3/8/2012 | 3/8/2012 | P | FAIL |
Jim Johnson
|
|
|
Phone #: ###-#### >> Inspection requested via web by James Walsh test failed on D W V need to retest. need to remove all fernco coupling,s and replace with approved shielded band coupling,s by kit sink vent, lav vent, and at cast iron to abs in crawl space. need nail plates at water heater bottom plate on water lines called contractor will recall when ready
|