Information based on query as of Thursday, July 18, 2024.
Permit Information
Permit NumberPLM12-01037
StatusFinaled
Name CELTIC PLUMBING
Site Address 5506 W OVERLAND RD
Project NameCasablanca Cuban Grill
Customer Number 
ePlanReviewNo
Description
install 1/2 RP and 3/4 Condinsate
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final5/30/20125/30/20125/30/2012PPASS
DetailsJim Johnson
nile- please call before going out Phone #: ###-####
Other5/16/20125/17/20125/17/2012APART
DetailsJim Johnson
10:30 walk through with united water made wake through with Bill T. water purveyor with united water. as per upc 2003 and cross control connection manual 6th edition need to provide additional backflow protection on following equipment 1. need toprovide a double check for premises protection on main water supply line with an approved expansion tank. 2.need to provide an approved backflow device on lawn sprinkler. 3. needR.P. on coffee maker 4. need double check on tea maker 5. need R P on ice machine (water cool side only ) 6. replace or repair vacuum breaker on dishwasher. 7. remove filter on water softner or provide R P on softner 8. provide hose bib vacuum breaker on hose bib on hot water side of water heater or remove hose bib.
Final5/16/20125/16/20125/16/2012PPART
DetailsJim Johnson
Nile Phone #: ###-#### need to make walk through for additional backflows with united water