Final | 11/15/2013 | 11/18/2013 | 11/18/2013 | A | PASS |
Jim Johnson
|
|
|
JOB CONTACT - MARK ###-#### Phone #: ###-#### >> Inspection requested via web by BECCA DUMMER
|
Final | 11/5/2013 | 11/7/2013 | 11/7/2013 | P | FAIL |
Jim Johnson
|
|
|
JOB CONTACT IS ROB Phone #: ###-#### >> Inspection requested via web by ADAM WARR building locked up no access left notice on site contractor to recall for final
|
Final | 11/5/2013 | 11/6/2013 | 11/5/2013 | P | CANC |
Jim Johnson
|
|
|
JOB CONTACT IS ROB Phone #: ###-#### >> Inspection requested via web by ADAM WARR Inspection cancelled from web by: ADAM WARR
|
Groundwork | 10/2/2013 | 10/3/2013 | 10/3/2013 | A | PASS |
Jim Johnson
|
|
|
groundwork and rough-in test ok ok to cover
|
Plumbing Rough-in | 10/2/2013 | 10/2/2013 | 10/2/2013 | P | FAIL |
Jim Johnson
|
|
|
JOB CONTACT - DAVID ###-#### Phone #: ###-#### >> Inspection requested via web by BECCA DUMMER as per I S P C 2009 311.3 no waste connection shall be made to a closet bend or stub of a water closet need to move connection down stream of water closet connection reschedule inspection for 10/3/2013 am
|
Plumbing Rough-in | 10/1/2013 | 10/1/2013 | 10/1/2013 | P | FAIL |
Jim Johnson
|
|
|
CONTACT IS DAVID ###-#### Phone #: ###-#### >> Inspection requested via web by LENNIE BUSS horizontial wet venting is approved for residential use only need to repipe water closet with an approved vent called contractor will recall when ready
|