Information based on query as of Wednesday, June 26, 2024.
Permit Information
Permit NumberPLM14-02897
StatusFinaled
Name PAIGE MECHANICAL GROUP INC
Site Address 1004 W ROYAL BLVD
Project Name 
Customer Number14.5690
ePlanReviewNo
Description
Plumbing Permit - New: DWV, Domestic Water, Rough in and trim, fixtures, electric water heaters
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final8/24/20158/25/20158/25/2015APASS
DetailsEric Strole
please call Jake with any questions
Phone #: ###-#### Inspection requested via web by Nicholas Paige
Final8/14/20158/17/20158/17/2015APART
DetailsEric Strole
Phone #: ###-#### Inspection requested via web by Nicholas Paige-2nd , 3rd & 4th flr final complete.
Final8/14/20158/14/20158/14/2015PPART
DetailsBill VanDegrift
Phone #: ###-#### Inspection requested via web by Nicholas Paige temp occ on floors 2,3 and 4 ok
Final8/13/20158/14/20158/14/2015ACANC
DetailsJim Little
Phone #: ###-#### Inspection requested via web by Nicholas Paige
>cancelled per jake
Final8/12/20158/13/20158/13/2015ANR
DetailsJim Little
Final8/11/20158/12/20158/12/2015ANR
DetailsEric Strole
Not ready
Final8/10/20158/11/20158/11/2015APART
DetailsEric Strole
Phone #: ###-#### Inspection requested via web by Nicholas Paige-4th flr units 401 thru 407 & 409 thru 415 pass.
Final8/10/20158/10/20158/10/2015PPART
DetailsEric Strole
please let jake know if you have any questions Phone #: ###-#### Inspection requested via web by Nicholas Paige-2nd flr final complete.
Final8/7/20158/7/20158/7/2015APART
DetailsEric Strole
Units 301 thru 317. 344, 343 pass
Water and/or Sewer8/7/20158/7/20158/7/2015ACANC
DetailsEric Strole
Final8/6/20158/7/20158/7/2015AFAIL
DetailsEric Strole
Units 218,220,318,320,418,420,518,520 water heaters are under sized per the 2009 ISPC table 5-1. Need a minimum of a 67 1st hr recovery rate.
Final8/5/20158/6/20158/6/2015ANR
DetailsEric Strole
this is a partial final for 3rd floor east Phone #: ###-#### Inspection requested via web by Nicholas Paige
Final8/4/20158/5/20158/5/2015AFAIL
DetailsEric Strole
2nd floor east Partial final Phone #: ###-#### Inspection requested via web by Nicholas Paige-Units 243 thru 244 fail, water heaters are undersized.
Final8/4/20158/4/20158/4/2015PFAIL
DetailsBill VanDegrift
water heaters installed do not meet the first hour rating of ISPC table 501
Final8/3/20158/4/20158/4/2015AFAIL
DetailsEric Strole
final for 2nd floor east Wing only Phone #: ###-#### Inspection requested via web by Nicholas Paige-Units 201 thru 218 water heaters are under sized. (2 bath 4 bedroom require a 67 gallon first hour recovery rate and a 4 bath 4 bedroom requires a 80 gallon first hour recovery rate.)
Plumbing Rough-in5/27/20155/28/20155/28/2015APART
DetailsEric Strole
overheads- please call jake with any questions. Phone #: ###-#### Inspection requested via web by Nicholas Paige-Hangers in garage overhead pass
Plumbing Rough-in5/26/20155/26/20155/26/2015PPASS
DetailsEric Strole
please call Jake with any questions Phone #: ###-#### Inspection requested via web by Nicholas Paige-East wing rough-in complete.
Water and/or Sewer5/21/20155/22/20155/22/2015PPART
DetailsEric Strole
Call jake with queations Phone #: ###-#### Inspection requested via web by Nicholas Paige-DWV in units 417,517 pass. Test on water in units 515,516,518 pass.
Plumbing Rough-in5/21/20155/22/20155/22/2015APART
DetailsEric Strole
Test on water in units 514,511,512,513,542,543 pass. Test on dwv in units 411,412,413,414,415,416,417,511,513,513,514,515,516,517,518,418 pass.
Plumbing Rough-in5/21/20155/21/20155/21/2015PCANC
DetailsEric Strole
please call jake if u have questions Phone #: ###-#### Inspection requested via web by Nicholas Paige
Plumbing Rough-in5/21/20155/21/20155/21/2015ACANC
DetailsEric Strole
Plumbing Rough-in5/20/20155/21/20155/21/2015APART
DetailsEric Strole
please call jake with questions
Phone #: ###-#### Inspection requested via web by Nicholas Paige-Test on dwv in units 409,410,442,443,444,509,510,542,543,544 pass. Test on water in units 507,508,509,510, 544 pass. Test on mains pass.
Plumbing Rough-in5/20/20155/20/20155/20/2015PCANC
DetailsEric Strole
Water and/or Sewer5/20/20155/20/20155/20/2015PCANC
DetailsEric Strole
Phone #: ###-#### Inspection requested via web by Nicholas Paige
Plumbing Rough-in5/19/20155/20/20155/20/2015APART
DetailsEric Strole
please let jake know if you have any questions Phone #: ###-#### Inspection requested via web by Nicholas Paige-Test on DWV in units 404,405,406,407,408,504,505,506,507,508 pass. Test on water in units 501,502,503,504,505,506 pass.
Plumbing Rough-in5/15/20155/18/20155/18/2015APART
DetailsEric Strole
please call jake with any questions. Phone #: ###-#### Inspection requested via web by Nicholas Paige-Test on water and dwv in units 401,402,403 pass. Test on dwv in units 501,502,503 pass.
Plumbing Rough-in5/13/20155/14/20155/14/2015APART
DetailsEric Strole
2nd and 3rd flr units rough-in complete
Plumbing Rough-in5/12/20155/12/20155/12/2015PPART
DetailsEric Strole
DWV in units 320,319,318,317,316,315,314,313,312,311,310,309 pass. Test on water in units 415,414,413,412,411,410,409,407,406,405,404,403,402,444,443,442 pass.
Plumbing Rough-in5/11/20155/11/20155/12/2015PFAIL
DetailsEric Strole
please call jake with any question. this is for the east wing Phone #: ###-#### Inspection requested via web by Nicholas Paige-Test on water in units 430,429,428,427,426,425,424,423,422,421,420,419,418,417,416 pass. Waste in units 320,319,318,317,316,315,314,313,312,311,310,309 fail.Need to fix all flat and backgraded dwv and retest.
Water and/or Sewer4/24/20154/27/20154/27/2015ACANC
DetailsEric Strole
Phone #: ###-#### Inspection requested via web by Nicholas Paige
Plumbing Rough-in4/23/20154/23/20154/23/2015PPART
DetailsEric Strole
please call jake with any questions. this is an east side partial rough in Phone #: ###-#### Inspection requested via web by Nicholas Paige-Test on dwv & water in units 242,243,244 pass. Test on water in units 342,343,344 pass.
Other4/16/20154/17/20154/17/2015APART
DetailsBill VanDegrift
onsite conference inspection for tomorrow am to talk about island venting with plumbing inspector. Please note that we would like Eric Strole and Bill Vandegrift to attend and meet Jake. Phone #: ###-#### Inspection requested via web by Nicholas Paige

went over island sink venting. only approved on true island sinks, continue with island sink venting on the rest.
Plumbing Rough-in4/15/20154/16/20154/16/2015PPART
DetailsEric Strole
Units 201 thru 220 rough-in pass. Units 301 thru 320 water test pass.
Plumbing Rough-in4/15/20154/15/20154/15/2015PPART
DetailsEric Strole
please call jake for questions Phone #: ###-#### Inspection requested via web by Nicholas Paige-Units 201,202,203 0k for cover.
Plumbing Rough-in4/6/20154/7/20154/7/2015APART
DetailsEric Strole
please call Jake with any questions Phone #: ###-#### Inspection requested via web by Nicholas Paige-DWV & water test pass and ok to cover lids only in units 207,208,209,210,211,212. Need bottom plate nailplates.Test on water in units 307,308,309,310,311,312 pass.
Plumbing Rough-in3/31/20154/1/20154/1/2015APART
DetailsEric Strole
NE 2nd floor Rough In inspection Phone #: ###-#### Inspection requested via web by Nicholas Paige-Test on water in units 201,202,203,204,205,206 pass.OK to cover lids in those unit only. Need to cut san tees out of kitcken stacks and cap off extra 2" waste lines.Need to fix leaks on dwv in those units and nail plate bottom plates. - Test on water in units 301,302,303,304,305 & 306 pass.
Plumbing Rough-in2/24/20152/25/20152/25/2015APART
DetailsEric Strole
Please call jake with any questions Phone #: ###-#### Inspection requested via web by Nicholas Paige-Corridors east side 1st flr ok to rock 24" down.
Other1/27/20151/28/20151/28/2015ADONE
DetailsEric Strole
conference to discuss manifold connections. mock up is done Phone #: ###-#### Inspection requested via web by Nicholas Paige-Conferance,Need to seperate waterlines so not rubbing against wood.
Water and/or Sewer12/11/201412/11/201412/11/2014PPART
DetailsEric Strole
under ground interceptor vent inspection Phone #: ###-#### Inspection requested via web by Nicholas Paige-Ground work is complete
Water and/or Sewer12/9/201412/10/201412/10/2014PPART
DetailsDaryl Spivey
24 hr test on flammable intercepter ok..........ds
Groundwork12/8/201412/9/201412/9/2014PPART
DetailsEric Strole
please call Jake with any questions
Phone #: ###-#### Inspection requested via web by Nicholas Paige-ground work complete except vents for interceptor.
Groundwork12/3/201412/4/201412/4/2014PPART
DetailsEric Strole
please call jake with any questions Phone #: ###-#### Inspection requested via web by Nicholas Paige-Section complete is marked on plans.
Water and/or Sewer12/2/201412/2/201412/2/2014PPART
DetailsEric Strole
this is a water main inspection. please call jake with any questions. Phone #: ###-#### Inspection requested via web by Nicholas Paige-Water supply stub in and out of building ok.
Other11/26/201411/26/201411/28/2014PDONE
DetailsEric Strole
This stainless steel piping has no testing agency approval marking on pipe except a number from table 6-4 of 2009 ISPC minus the testing agency marking and has no other approval markings and no installation instructions. Bill Vandegrift has a paper of a mill testing and has approved this piping for the potable water system and I am supposed to get installation instructions from the manufacturer.
Other11/26/201411/26/201411/28/2014PPASS
DetailsBill VanDegrift
2pm went over the stainless piping. Bill Carter will provide installation standards. Mill test seems correct for material.
Water and/or Sewer11/21/201411/24/201411/25/2014ACANC
DetailsEric Strole
this is a conference email aswell to discuss ss pipe. Phone #: ###-#### Inspection requested via web by Nicholas Paige
Water and/or Sewer11/21/201411/21/201411/21/2014PFAIL
DetailsEric Strole
Stainless needs listing
Groundwork11/21/201411/21/201411/21/2014APART
DetailsEric Strole
Call doran with questions Phone #: ###-#### Inspection requested via web by Nicholas Paige-section complete is marked on plans
Other11/18/201411/19/201411/19/2014ADONE
DetailsEric Strole
This was a conferance
Other11/17/201411/18/201411/18/2014PCANC
DetailsEric Strole