Final | 9/30/2015 | 9/30/2015 | 9/30/2015 | A | PASS |
Eric Strole
|
|
|
garage code 5050 Phone #: ###-#### Inspection requested via web by Boe Jares
|
Plumbing Rough-in | 7/23/2015 | 7/24/2015 | 7/24/2015 | P | PASS |
Eric Strole
|
|
|
Phone #: ###-#### Inspection requested via web by Boe Jares
|
Plumbing Rough-in | 7/22/2015 | 7/22/2015 | 7/22/2015 | A | FAIL |
Jim Little
|
|
|
Phone #: ###-#### Inspection requested via web by Boe Jares=======missing nail plates.2.leak at santee laundry tray.3. backgraded 3" on overhead at base of stairs.4.strap vent at 90 on two blocks over tub.5.mst shower must enter on horizontal not rolled.6.change out 4x3 closet bend to regular sweep at 4".
|
Groundwork | 6/17/2015 | 6/18/2015 | 6/18/2015 | A | PASS |
Eric Strole
|
|
|