Final | 9/29/2015 | 10/2/2015 | 10/2/2015 | P | PASS |
Eric Strole
|
|
|
Please inspect first thing after lunch. Homeowner Dallas Millington ###-####. Phone #: ###-#### Inspection requested via web by Mary LaFayette
|
Final | 9/22/2015 | 9/24/2015 | 9/24/2015 | A | FAIL |
Eric Strole
|
|
|
Please inspect first thing in AM. Homeowner Dallas Millington, ###-####. Please call when you are on your way. Phone #: ###-#### Inspection requested via web by Mary LaFayette-Need to put heat sheild around b-vent in upper section of cabinet. Need 1" clearance to combustables around b-vent. Need to run a 6" duct from water heater space to attic space for combustion air and remove dampers from lower combustion air register.
|