Final | 3/1/2016 | 3/2/2016 | 3/2/2016 | P | PASS |
Jim Little
|
|
|
venting adjustment per last inspection Phone #: ###-#### Inspection requested via web by ron pierce
|
Final | 2/24/2016 | 2/25/2016 | 2/25/2016 | A | FAIL |
Bill VanDegrift
|
|
|
Phone #: ###-#### Inspection requested via web by ron pierce common vent is undersized
|
Plumbing Rough-in | 2/17/2016 | 2/18/2016 | 2/18/2016 | P | PASS |
Jim Little
|
|
|
make changes per inspector Phone #: ###-#### Inspection requested via web by ron pierce >gas ok 20# test ok
|
Med/Gas Systems | 2/16/2016 | 2/17/2016 | 2/17/2016 | A | FAIL |
Jim Little
|
|
|
see manager onsite Phone #: ###-#### Inspection requested via web by ron pierce >cannot test against live meter with one ball valve, must use two with an open tee in between. per IFGC 406.1.4 or UPC 1214.1.5
|