Final | 6/21/2016 | 6/22/2016 | 6/22/2016 | A | PASS |
Jim Little
|
|
|
Home owner will be there. Nancy Ness is her name. Thankyou I will be unavailable more than likely Phone #: ###-#### Inspection requested via web by travis prawitz
|
Plumbing Rough-in | 4/27/2016 | 4/27/2016 | 4/27/2016 | A | PASS |
Jim Little
|
|
|
>washer box work was existing,
|
Plumbing Rough-in | 4/24/2016 | 4/26/2016 | 4/26/2016 | P | FAIL |
Jim Little
|
|
|
Kitchen remodel. House will be open. Call me before you go so I can make sure it is open for you. Thanks Travis Evolution Plumbing Phone #: ###-#### Inspection requested via web by travis prawitz >Use approved transition bands @ ABS >washer box trap arm needs to tie into a santee instead of a wye/45 >vent needs to reduce at santee, not mid run >add washer box to permit
|