DOC - Permit Finaled | 6/3/2016 | 6/3/2016 | 6/3/2016 | P | PASS |
Jim Little
|
|
|
|
Water and/or Sewer | 6/3/2016 | 6/3/2016 | 6/3/2016 | A | PASS |
Jim Little
|
|
|
Inspection requested via web by Travis Caywood
|
Water and/or Sewer | 6/2/2016 | 6/2/2016 | 6/2/2016 | P | FAIL |
Jim Little
|
|
|
Its ready this time Phone #: ###-#### Inspection requested via web by Travis Caywood >need blue 18 AWG tracer wire with water service. >IPS 717 pvc glue is not one step and needs a purple primer applied. no primer was used. redo glue ftgs and retest. > >water service needs to be 1-1/4" to accommadate the 4.5 bathrooms.
|
Water and/or Sewer | 6/1/2016 | 6/2/2016 | 6/2/2016 | A | NR |
Jim Little
|
|
|
Phone #: ###-#### Inspection requested via web by Travis Caywood
|