Final12/27/201612/27/201612/27/2016PPASS
DetailsDan Ediger
The door is 1052
Dan we did not put a double check for the coffee make because they are not going to but on in
Let me know if this will work before you come and inspect
Thanks rob ###-#### Phone #: ###-#### Inspection requested via web by robert goodson
Final12/19/201612/19/201612/19/2016PPART
DetailsDan Ediger
0152 Phone #: ###-#### Inspection requested via web by robert goodson.
1. Install a thermal expansion tank on the cold side of the water heater and downstream of the double check valve. 608.3
2. Install a double check valve or RP (per plans), for the commercial coffee maker.
3. Install a temperature limiting device on the public restroom faucet that meets ASSE 1070.
413.1.
Plumbing Rough-in9/23/20169/23/20169/23/2016PPASS
DetailsEric Strole
Water and/or Sewer9/23/20169/23/20169/23/2016PCANC
DetailsEric Strole
Code 1052 Phone #: ###-#### Inspection requested via web by robert goodson
Groundwork8/23/20168/23/20168/23/2016PPASS
DetailsBill VanDegrift
0152 Phone #: ###-#### Inspection requested via web by robert goodson gw ok with access to service connection.