Final | 6/15/2017 | 6/16/2017 | 6/16/2017 | A | PASS |
Eric Strole
|
|
|
jody Phone #: ###-####
|
Final | 6/14/2017 | 6/14/2017 | 6/14/2017 | P | NR |
Daryl Spivey
|
|
|
CHECK THE SPRINKLER. the house looked ok the other day. Jody is going to add the sprinkler to his permit. they had green piping upstream of the dcva and it wasn't tested and it was covered up. dcva not tested and 100 psi not replaced yet..........ds
|
Final | 6/7/2017 | 6/7/2017 | 6/7/2017 | P | FAIL |
Bill VanDegrift
|
|
|
Jody Phone #: ###-#### trim is ok 1) secure a permit for the lawn sprinkler backflow preventor 2) expose connections to main 3) replace all upstream piping with approved material 4) have DCVA certified 5) call for inspection
|
PLM-Aging Inspection | 5/25/2017 | 5/25/2017 | 5/25/2017 | | PART |
Eric Strole
|
|
|
No calls
|
Plumbing Rough-in | 10/31/2016 | 10/31/2016 | 10/31/2016 | P | PASS |
Daryl Spivey
|
|
|
Jody Phone #: ###-####
|