Permit Information
Permit NumberPLM17-03869
StatusFinaled
Name ALTA CONSTRUCTION
Site Address 555 S COLE RD
Project Name 
Customer Number 
ePlanReviewNo
Description
New: Site utilities, water, sewer, grading
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Water and/or Sewer12/21/201712/22/201712/22/2017APASS
DetailsDan Ediger
DOC - Permit Finaled12/22/201712/22/201712/22/2017PPASS
DetailsDan Ediger
Water and/or Sewer12/21/201712/21/201712/21/2017PPART
DetailsDan Ediger
Phone #: ###-#### Inspection requested via web by Katherine Creekbaum.
OK to cover first 60'.
Water and/or Sewer11/20/201711/21/201711/21/2017APASS
DetailsDan Ediger
Waterline Phone #: ###-#### Inspection requested via web by Katherine Creekbaum
Water and/or Sewer10/24/201710/24/201710/24/2017PPART
DetailsDan Ediger
OK to cover. Need t install tank vent flamable vapor vent after backfill
Water and/or Sewer10/23/201710/23/201710/23/2017AFAIL
DetailsDan Ediger
THIS WAS CALLED IN ON THE GRADING PERMIT GRD17-00025 Jim Wellman

Requesting an inspection for 1500 gallon grease interceptor. Not sure what type of inspection is needed. I talked to Dan Ediger Plumbing inspector looked at it and need him to re-inspect tank. Phone #: ###-#### Inspection requested via web by Jim Wellman.
1. 24 houir test passed.
2. The downstream vent must be taken off the upper half of the sewer. see correction notice drawing.
3. Use wye branch fittings on the vent and a drainage fitting on the 90.
4. Add a flammable vapor vent to the tank itself. see diagram provided with the correction notice.
Water and/or Sewer10/12/201710/13/201710/13/2017PPART
DetailsDan Ediger
partial water/sewer Phone #: ###-#### Inspection requested via web by Katherine Creekbaum. Water service and sewer ok to cover.
No approved plans on the job. Spoke with the builder and explained they taking responsiblities for any changes required on the approved set. Grease trap needs 24 hour test.