Information based on query as of Wednesday, July 17, 2024.
Permit Information
Permit NumberPLM17-04080
StatusFinaled
Name PRIME PLUMBING LLC
Site Address 124 W SKYLARK DR
Project Name 
Customer Number 
ePlanReviewNo
Description
Complete Plumbing Installation: New Construction Plumbing Rough-in-this includes the outside water line as well
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final6/18/20196/19/20196/19/2019APASS
DetailsDaryl Spivey
Phone #: ###-#### Inspection requested via web by Kevin Smith
PLM-Aging Inspection4/15/20194/15/20194/15/2019 PEND
DetailsDaryl Spivey
no calls
PLM-Aging Inspection1/14/20191/14/20191/14/2019 PEND
DetailsDaryl Spivey
no calls
PLM-Aging Inspection10/15/201810/15/201810/15/2018 PASS
DetailsDaryl Spivey
wip
Plumbing Rough-in7/16/20187/17/20187/17/2018PPASS
DetailsDaryl Spivey
Phone #: ###-#### Inspection requested via web by Kevin Smith
water service ok also.........ds
Plumbing Rough-in7/12/20187/13/20187/13/2018APART
DetailsDaryl Spivey
Kevin Phone #: ###-####
water ok.....waste test failed.....ds
Water and/or Sewer7/12/20187/13/20187/13/2018AFAIL
DetailsDaryl Spivey
Kevin-water line only Phone #: ###-####
need tracer wire and cannot use pex coupling under concrete.........ds
Groundwork12/15/201712/18/201712/18/2017APASS
DetailsDaryl Spivey
Kevin Phone #: ###-####
Groundwork10/26/201710/27/201710/27/2017APASS
DetailsDaryl Spivey
Kevin Phone #: ###-####
Groundwork10/20/201710/23/201710/23/2017AFAIL
DetailsDan Ediger
Kevin Phone #: ###-####
1. Pipes are flat and backgrading. Install with a 1/4 per foot grade.
2. Extend the drain outside the house.
3. Wrap all piping in contact with the cement.