Final | 3/28/2018 | 3/29/2018 | 3/29/2018 | A | PASS |
Dan Ediger
|
|
|
Please call ahead for access to Neil at ###-####. Thanks Phone #: ###-#### Inspection requested via web by Todd Vitek
|
Final | 3/20/2018 | 3/21/2018 | 3/21/2018 | A | FAIL |
Dan Ediger
|
|
|
Phone #: ###-#### Inspection requested via web by Todd Vitek. 1. Install a t&p on the water heater and pipe to drain. 2. The gas flex on the water heater is too small. 3. Install a 3" drip leg on the water heater outlet. 4. Pressure test the water heater flue. 5. Raise the top of the water heater to the top of the door jam for fau clearance.
|
Water and/or Sewer | 11/28/2017 | 11/29/2017 | 11/29/2017 | A | CANC |
Dan Ediger
|
|
|
Phone #: ###-#### Inspection requested via web by Mike Sanders
|
Plumbing Rough-in | 11/5/2017 | 11/6/2017 | 11/6/2017 | A | PASS |
Dan Ediger
|
|
|
Phone #: ###-#### Inspection requested via web by Todd Vitek
|
Plumbing Rough-in | 11/2/2017 | 11/3/2017 | 11/3/2017 | P | FAIL |
Dan Ediger
|
|
|
the building is in the back left of lot.. building sewer and water are not in yet. Phone #: ###-#### Inspection requested via web by Todd Vitek. Failed the dwv pressure test. All else ok.
|