Information based on query as of Wednesday, July 17, 2024.
Permit Information
Permit NumberPLM18-00766
StatusFinaled
Name RM MECHANICAL
Site Address 13601 W MCMILLAN RD Unit: STE 104
Project Name 
Customer Number18-030
ePlanReviewNo
Description
New: 18-030 Paddles Up Poke - hook up new owner supplied fixtures
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final2/27/20182/27/20182/27/2018PPASS
DetailsDan Ediger
Contact Name: Josh Wilson - Please Call Josh for door code. Phone #: ###-#### Inspection requested via web by Melissa Kaae
Final2/22/20182/23/20182/23/2018AFAIL
DetailsDan Ediger
Contact Name: Josh Wilson
PLEASE CALL JOSH FOR DOOR LOCK CODE. Phone #: ###-#### Inspection requested via web by Melissa Kaae.
1. The indirect waste must have an air gap equal to 2x the diameter of the pipe.
2. The chemical feed at the mop sink must have it's own valve or a connection on the faucet that won't allow the faucet to be left on.
3. Pipe the grease trap per manufacturs instructions and plan specfications.
4. Add tempering valves on the public lavatories. Required with a change of tenant.