Permit Information
Permit NumberPLM18-01403
StatusFinaled
Name RM MECHANICAL
Site Address 8000 S FEDERAL WAY
Project NameC30616 B37 Office Building
Customer Number18-039
ePlanReviewNo
Description
New: FURNISH AND INSTALL SANITARY WASTE AND VENT, STORM DRAINS, DOMESTIC WATER, AND FINISH FIXTURES.
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final1/29/20191/29/20191/29/2019PPASS
DetailsEric Strole
Site contact: Martin Yingling ###-####
Please call 1 hour prior to inspection. Phone #: ###-#### Inspection requested via web by RM Mechanical
Card not on site to sign1/29/20191/29/20191/29/2019PPASS
DetailsEric Strole
Site contact: Martin Yingling ###-####
Please call 1 hour prior to inspection. Phone #: ###-#### Inspection requested via web by RM Mechanical
Plumbing Rough-in1/3/20191/4/20191/4/2019APASS
DetailsEric Strole
Phone #: ###-#### Inspection requested via web by RM Mechanical-Locker room rough-in pass.
Final12/21/201812/24/201812/24/2018APART
DetailsEric Strole
2nd Floor Phone #: ###-#### Inspection requested via web by RM Mechanical-2nd floor final ok.
Final12/7/201812/10/201812/10/2018APART
DetailsEric Strole
Final for 3rd floor and 1st floor lobby Phone #: ###-#### Inspection requested via web by RM Mechanical-Temp final 3rd flr & lobby ok, still need some backflows for coffee, expresso and need labeling.
Final12/6/201812/7/201812/7/2018PNR
DetailsEric Strole
Final for 3rd floor and 1st floor lobby Phone #: ###-#### Inspection requested via web by RM Mechanical-Will give a temp final when water is safe to drink. They are chlorinating the waterlines at this time.
Roof Drains11/29/201811/30/201811/30/2018APART
DetailsEric Strole
Phone #: ###-#### Inspection requested via web by RM Mechanical-Roofdrains for link between building 36 & 37 pass.
Groundwork11/26/201811/26/201811/26/2018APASS
DetailsEric Strole
Phone #: ###-#### Inspection requested via web by RM Mechanical
Plumbing Rough-in11/14/201811/15/201811/15/2018APASS
DetailsMatt Wrobel
Phone #: ###-#### Inspection requested via web by RM Mechanical
vent for urinal and lav shaft wall
Plumbing Rough-in10/8/201810/9/201810/9/2018APART
DetailsEric Strole
Waste/vent ; water Area main bathroom group Phone #: ###-#### Inspection requested via web by RM Mechanical-Section complete is marked in test result book.
Plumbing Rough-in10/2/201810/2/201810/2/2018PPART
DetailsEric Strole
Potable water rough in level one Phone #: ###-#### Inspection requested via web by RM Mechanical-Section complete is marked in test result book.
Plumbing Rough-in9/26/20189/27/20189/27/2018APART
DetailsEric Strole
First Floor Area C Restroom Waste/Vent ; Water Phone #: ###-#### Inspection requested via web by RM Mechanical-Section passed is marked in test result book. Missing nailplates on waterlines and hosebibs are backgraded.
Plumbing Rough-in9/11/20189/12/20189/12/2018APART
DetailsEric Strole
Waste ; Vent rough in first floor Phone #: ###-#### Inspection requested via web by RM Mechanical-Section inspected is marked on plans.
Plumbing Rough-in9/10/20189/10/20189/10/2018PPART
DetailsEric Strole
Waste/vent area C level 2. Phone #: ###-#### Inspection requested via web by RM Mechanical-Section passed in marked on plans.
Plumbing Rough-in9/7/20189/7/20189/7/2018PPART
DetailsBill VanDegrift
Waste ; Vent Rough In Area C Phone #: ###-#### Inspection requested via web by RM Mechanical 3rd floor restroom repipe test ok
Plumbing Rough-in9/5/20189/5/20189/5/2018PFAIL
DetailsEric Strole
Waste/Vent Carriers Third Floor Phone #: ###-#### Inspection requested via web by RM Mechanical-Cannot use a 4" cross san tee for horizontal to vertical coming in at the same level.
Roof Drains8/21/20188/21/20188/21/2018PPART
DetailsEric Strole
Roof Drains Test Phone #: ###-#### Inspection requested via web by RM Mechanical-Section complete is marked on plans.
Plumbing Rough-in8/21/20188/21/20188/21/2018PPART
DetailsEric Strole
Waste ; Vent Test Phone #: ###-#### Inspection requested via web by RM Mechanical-Section complete is marked on plans.
Plumbing Rough-in8/15/20188/16/20188/16/2018APART
DetailsEric Strole
Waste ; Vent Rough In second floor area C Phone #: ###-#### Inspection requested via web by RM Mechanical-Section complete is marked on plans.
Plumbing Rough-in8/10/20188/13/20188/13/2018PPART
DetailsEric Strole
Waste and Vent/Water Rough in Phone #: ###-#### Inspection requested via web by RM Mechanical-Section complete is marked on plans.
Plumbing Rough-in8/2/20188/3/20188/3/2018ACANC
DetailsEric Strole
Waste ; Vent Rough In Phone #: ###-#### Inspection requested via web by RM Mechanical
Plumbing Rough-in7/30/20187/31/20187/31/2018AFAIL
DetailsEric Strole
Waste ; Vent Rough In. Phone #: ###-#### Inspection requested via web by RM Mechanical-Need to fix reverse grade on dwv.
Roof Drains7/26/20187/27/20187/27/2018APART
DetailsEric Strole
Rough in Phone #: ###-#### Inspection requested via web by RM Mechanical-Section complete is marked on plans.
Plumbing Rough-in7/26/20187/27/20187/27/2018APART
DetailsEric Strole
Phone #: ###-#### Inspection requested via web by RM Mechanical-Section complete is marked on plans.
Roof Drains7/25/20187/26/20187/26/2018APART
DetailsEric Strole
Phone #: ###-#### Inspection requested via web by RM Mechanical-Section complete is marked on plans.
Plumbing Rough-in7/25/20187/26/20187/26/2018APART
DetailsEric Strole
Phone #: ###-#### Inspection requested via web by RM Mechanical-Section complete is marked on plans.
Roof Drains7/24/20187/25/20187/25/2018APART
DetailsEric Strole
Rough In Phone #: ###-#### Inspection requested via web by RM Mechanical-Section complete is marked on plans.
Plumbing Rough-in7/24/20187/25/20187/25/2018APART
DetailsEric Strole
Phone #: ###-#### Inspection requested via web by RM Mechanical-Section complete is marked on plans.
Roof Drains7/20/20187/23/20187/23/2018PPART
DetailsEric Strole
Contact: Eric Frank
Roof Drain Rough In Phone #: ###-#### Inspection requested via web by RM Mechanicall-Section complete is marked on plans.
Plumbing Rough-in7/20/20187/23/20187/23/2018PPART
DetailsEric Strole
Contact: Eric Frank
Waste ; Vent Rough In Phone #: ###-#### Inspection requested via web by RM Mechanical-Section complete is marked on plans.
Plumbing Rough-in7/19/20187/20/20187/20/2018APART
DetailsEric Strole
Waste ; Vent Rough In Phone #: ###-#### Inspection requested via web by RM Mechanical-Need to fix reverse grade on dwv in bathroom group. Section passed is marked on plans.
Roof Drains7/19/20187/20/20187/20/2018APART
DetailsEric Strole
Roof Drain Rough In Phone #: ###-#### Inspection requested via web by RM Mechanical-Section complete marked on plans.
Roof Drains7/16/20187/17/20187/17/2018APART
DetailsEric Strole
Roof Drain Rough In Phone #: ###-#### Inspection requested via web by RM Mechanical-Section complete is marked on plans.
Plumbing Rough-in7/16/20187/17/20187/17/2018APART
DetailsEric Strole
Waste ; Vent Rough In Phone #: ###-#### Inspection requested via web by RM Mechanical-Section complete is marked on plans.
Plumbing Rough-in7/13/20187/13/20187/13/2018APART
DetailsEric Strole
Rough-in on Roof Drains and Waste Vents. Dennis White is the Site Contact, Dennis White''s Phone Number is ###-####. Phone #: ###-#### Inspection requested via web by RM MechanicalRough-in on Roof Drains and Waste Vents. Dennis White is the Site Contact, Dennis White''s Phone Number is ###-####. Phone #: ###-#### Inspection requested via web by RM MechanicalRough-in on Roof Drains and Waste Vents. Dennis White is the Site Contact, Dennis White''s Phone Number is ###-####. Phone #: ###-#### Inspection requested via web by RM Mechanical-Section complete is marked on plans.
Roof Drains7/12/20187/13/20187/13/2018APART
DetailsEric Strole
Rough-in on Roof Drains and Waste Vents. Dennis White is the Site Contact, Dennis White''s Phone Number is ###-####. Phone #: ###-#### Inspection requested via web by RM MechanicalRough-in on Roof Drains and Waste Vents. Dennis White is the Site Contact, Dennis White''s Phone Number is ###-####. Phone #: ###-#### Inspection requested via web by RM Mechanical
Plumbing Rough-in7/10/20187/11/20187/11/2018APART
DetailsEric Strole
Waste ; Vent Level 3 Area A Riser 1

Contact: Dennis Phone #: ###-#### Inspection requested via web by RM Mechanical-Section complete is marked on plans.
Roof Drains7/10/20187/11/20187/11/2018APART
DetailsEric Strole
Roof Drain ; Over Flow Level 3 Area A Riser 1

Contact: Dennis Phone #: ###-#### Inspection requested via web by RM Mechanical-Section complete is marked on plans.
Water and/or Sewer7/10/20187/11/20187/10/2018ACANC
DetailsEric Strole
Waste ; Vent Level 3 Area A Riser 1

Contact: Dennis Phone #: ###-#### Inspection requested via web by RM Mechanical
Water and/or Sewer5/23/20185/24/20185/24/2018APART
DetailsEric Strole
Water service riser into the building. Contact: Dennis White Phone #: ###-#### Inspection requested via web by RM Mechanical-Water service stub into building pass.
Groundwork5/16/20185/16/20185/16/2018APART
DetailsEric Strole
Underground Sewer Area C
Contact: Dennis White ###-#### Phone #: ###-#### Inspection requested via web by RM Mechanical-All dwv and roof drains in slab complete. Still need water service.
Water and/or Sewer5/15/20185/16/20185/16/2018ACANC
DetailsEric Strole
Underground Sewer Area C
Contact: Dennis White ###-#### Phone #: ###-#### Inspection requested via web by RM Mechanical
Groundwork5/4/20185/4/20185/4/2018APART
DetailsEric Strole
G/W on unisex bathrooms pass.
Water and/or Sewer5/3/20185/4/20185/4/2018ACANC
DetailsEric Strole
Underground Sanitary Sewer Area C.

Contact: Dennis White ###-#### Phone #: ###-#### Inspection requested via web by Melissa Kaae
Water and/or Sewer4/24/20184/25/20184/25/2018APART
DetailsEric Strole
Underground Sanitary Sewer - Area B

Contact: Dennis White ###-#### Phone #: ###-#### Inspection requested via web by Melissa Kaae-Area A & B g/w complete.
Roof Drains4/19/20184/20/20184/20/2018APART
DetailsEric Strole
Contact: Dennis White ###-####

Area B underground Phone #: ###-#### Inspection requested via web by Melissa Kaae-Section of roof drain tested pass.
Water and/or Sewer4/16/20184/17/20184/17/2018APART
DetailsEric Strole
Contact: Dennis White

Underground Sanitary Sewer Phone #: ###-#### Inspection requested via web by Melissa Kaae-Section complete ok to cover.
Groundwork4/9/20184/10/20184/10/2018APART
DetailsEric Strole
Requesting partial underground rough-in inspection.

Contact: Dennis White Phone #: ###-#### Inspection requested via web by Melissa Kaae-Need to resubmit plans for sections of g/w that is not per the approved plans. Sections that are per the plans are ok to cover.
Groundwork4/9/20184/9/20184/9/2018PPART
DetailsEric Strole
Requesting partial underground rough-in inspection.

Contact: Dennis White Phone #: ###-#### Inspection requested via web by Melissa Kaae-2-8" underslab roof drains north side of building test pass.
Plumbing Rough-in4/6/20184/9/20184/9/2018ANR
DetailsEric Strole
Requesting partial underground rough-in inspection.

Contact: Dennis White Phone #: ###-#### Inspection requested via web by Melissa Kaae