Information based on query as of Friday, August 16, 2024.
Permit Information
Permit NumberPLM18-03660
StatusFinaled
Name DOUBLE A PLUMBING ENT LLC
Site Address 9140 W EMERALD ST Unit: STE 110
Project NameLally's Spa
Customer Number 
ePlanReviewNo
Description
installing four floor sinks stations for foot wash, one water heater and additional floor sink.
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final10/30/201810/31/201810/31/2018PPASS
DetailsDan Ediger
juan Phone #: ###-####
Final10/19/201810/19/201810/19/2018PFAIL
DetailsDan Ediger
Phone #: ###-####
1. Pedicure waters must be fed through rp backflow prevention assemblies.
2. Pedicure and hairwash sinks must be draine through indirect waste. No "S: traps.
3. PEX must be more than 18" away from water heater connections.
4. Public lavs must have tempering valves installed.
Plumbing Rough-in8/27/20188/28/20188/28/2018APASS
DetailsBill VanDegrift
underground // Juan Phone #: ###-#### gw and ri ok