Information based on query as of Tuesday, July 16, 2024.
Permit Information
Permit NumberPLM18-04665
StatusExpired
Name LWH PROPERTIES LLC
Site Address 2923 N WOODY DR
Project NameSwanson Remodel
Customer Number 
ePlanReviewNo
Description
Homeowner Online - Alteration or Repair: Re Plumb of entire house
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
DOC - Permit Expired5/12/20205/12/20205/12/2020APASS
DetailsDaryl Spivey
no contact. bld expired
PLM-Aging Inspection5/12/20205/12/20205/12/2020 PASS
DetailsDaryl Spivey
expired
PLM-Aging Inspection2/11/20202/11/20202/11/2020 PEND
DetailsDaryl Spivey
left message...........ds
PLM-Aging Inspection11/12/201911/12/201911/12/2019 PASS
DetailsDaryl Spivey
Plumbing Rough-in8/13/20198/14/20198/14/2019APASS
DetailsDaryl Spivey
Mike Phone #: ###-####
Final8/12/20198/13/20198/13/2019ANR
DetailsDaryl Spivey
Jim Phone #: ###-####
conf, only........ds
Plumbing Rough-in8/7/20198/8/20198/8/2019AFAIL
DetailsDaryl Spivey
Mike-call for access Phone #: ###-####
test failed on waste, use wye fittings on horizontal drain connections and plumb outside water with required piping and fittings...........ds
Plumbing Rough-in7/26/20197/29/20197/29/2019AFAIL
DetailsMatt Wrobel
Mike Phone #: ###-####
1. 3 inch cleanout required for toilet
2. water lines in attic need to be insulated and tented
3. nailplates
4. wh vent needs insulation shield
5 all pipes under slab need to be. 2 inch minimum.
6. if poly line goingf down in bathroom is for sprinklers will need backflow protection
Other5/30/20195/30/20195/30/2019PPART
DetailsDaryl Spivey
bld permit obtained.........attached plg..............ds
Final1/28/20191/28/20191/28/2019PCANC
DetailsDaryl Spivey
Mike Phone #: ###-####
Plumbing Rough-in1/28/20191/28/20191/28/2019PFAIL
DetailsDaryl Spivey
Mike Phone #: ###-####
Plumbing has several code infractions. Also need a BLD permit to continue with work on project. Stop work issued by BLD inspector.. Bld sewer shall be 4 inch with 4 in. C/O.
doesnt meet cross sectional venting, fitting installed incorrectly and toilet not vented. Also water in cold spaces............ds