Information based on query as of Wednesday, July 3, 2024.
Permit Information
Permit NumberPLM18-05064
StatusFinaled
Name WATER TIGHT MECH & CONT SERVICES LL
Site Address 2404 W BANK DR Unit: 350
Project Name 
Customer Number 
ePlanReviewNo
Description
Addition: Gas piping
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final12/20/201812/21/201812/21/2018APASS
DetailsEric Strole
Phone #: ###-#### Inspection requested via web by Jeremy Paxman
Pressure Test12/6/201812/7/201812/7/2018APASS
DetailsEric Strole
Gas pressure test Phone #: ###-#### Inspection requested via web by Jeremy Paxman-20 lb gas test pass.
Pressure Test12/5/201812/6/201812/6/2018AFAIL
DetailsEric Strole
Gas presure test Phone #: ###-#### Inspection requested via web by Jeremy Paxman-Need to use a 30 lb gauge for a 20 lb test and need 2 valves with an open tee in the middle when testing against a live system.